TDT will be closed for Thanksgiving Holiday on November 26th and 27th.

Menu

Psychoacoustics publications

Listening experiments in people and animals, with sounds generated and timed by TDT systems.

1,902 papers

Frontiers in Psychology · Jan 2017

Onset-Duration Matching of Acoustic Stimuli Revisited: Conventional Arithmetic vs. Proposed Geometric Measures of Accuracy and Precision (opens in a new tab)

Björn Friedrich, Peter Heil

Abstract

Onsets of acoustic stimuli are salient transients and are relevant in humans for the perception of music and speech. Previous studies of onset-duration discrimination and matching focused on whether onsets are perceived categorically. In this study, we address two issues. First, we revisit onset-duration matching and measure, for 79 conditions, how accurately and precisely human listeners can adjust the onset duration of a comparison stimulus to subjectively match that of a standard stimulus. Second, we explore measures for quantifying performance in this and other matching tasks. The conventional measures of accuracy and precision are defined by arithmetic descriptive statistics and the Euclidean distance function on the real numbers. We propose novel measures based on geometric descriptive statistics and the log-ratio distance function, the Euclidean distance function on the positive-real numbers. Only these properly account for the fact that the magnitude of onset durations, like the magnitudes of most physical quantities, can attain only positive real values. The conventional (arithmetic) measures possess a convexity bias that yields errors that grow with the width of the distribution of matches. This convexity bias leads to misrepresentations of the constant error and could even imply the existence of perceptual illusions where none exist. This is not so for the proposed (geometric) measures. We collected up to 68 matches from a given listener for each condition (about 34,000 matches in total) and examined inter-listener variability and the effects of onset duration, plateau duration, sound level, carrier, and restriction of the range of adjustable comparison stimuli on measures of accuracy and precision. Results obtained with the conventional measures generally agree with those reported in the literature. The variance across listeners is highly heterogeneous for the conventional measures but is homogeneous for the proposed measures. Furthermore, the proposed measures show that listeners tend to under- rather than to overestimate the onset duration of the comparison stimuli. They further reveal effects of the stimulus carrier on accuracy and precision which are missed by the conventional measures. Our results have broad implications for psychophysical studies that use arithmetic measures to quantify performance when geometric measures should instead be used.

European Journal of Neuroscience · Jan 2017

Effect of preceding stimulation on sound localization and its representation in the auditory midbrain (opens in a new tab)

Tolnai S, Beutelmann R, Klump GM

Abstract

Prior stimulation can influence the perception of sound source location. Some psychophysical sound localization procedures differ in the amount of prior stimulation, which may affect measures of localization accuracy. If and how particularly the number of preceding stimuli affects sound localization and the neural representation of sound source position has not been investigated so far and will be the focus of the present report. We trained Mongolian gerbils in a left/right discrimination task where the target stimulus was preceded by silence or followed a number of reference stimuli. Localization thresholds decreased with the number of references presented before the target stimulus. The smallest thresholds were found after the presentation of a train of 5 reference stimuli and after silence. We recorded from units in the inferior colliculus (IC) of anaesthetized gerbils using virtual-acoustic space stimuli mimicking the ones used in the behavioural task and applied signal detection theory to compare behavioural and neurometric thresholds. We found that neurometric thresholds based on spike rate information of single units covered a wide range of threshold values but only neurometric thresholds that were based on responses of small populations of IC units reached consistently thresholds we also observed in the behavioural experiment. Unlike behavioural thresholds, however, neurometric thresholds were independent of the number of reference stimuli suggesting that processing stages downstream from the IC might better reflect the effect of prior stimulation.

Cerebral Cortex · Jan 2017

Who’s that Knocking at My Door? Neural Bases of Sound Source Identification (opens in a new tab)

Guillaume Lemaitre, John A Pyles, Andrea R Halpern, … Laurie M Heller

Abstract

When hearing knocking on a door, a listener typically identifies both the action (forceful and repeated impacts) and the object (a thick wooden board) causing the sound. The current work studied the neural bases of sound source identification by switching listeners' attention toward these different aspects of a set of simple sounds during functional magnetic resonance imaging scanning: participants either discriminated the action or the material that caused the sounds, or they simply discriminated meaningless scrambled versions of them. Overall, discriminating action and material elicited neural activity in a left-lateralized frontoparietal network found in other studies of sound identification, wherein the inferior frontal sulcus and the ventral premotor cortex were under the control of selective attention and sensitive to task demand. More strikingly, discriminating materials elicited increased activity in cortical regions connecting auditory inputs to semantic, motor, and even visual representations, whereas discriminating actions did not increase activity in any regions. These results indicate that discriminating and identifying material requires deeper processing of the stimuli than discriminating actions. These results are consistent with previous studies suggesting that auditory perception is better suited to comprehend the actions than the objects producing sounds in the listeners' environment.

Journal of the American Academy of Audiology · 2017

Using Microphone Technology to Improve Speech Perception in Noise in Children with Cochlear Implants (opens in a new tab)

Johnstone PM, Mills KET, Humphrey EL, et al.

Abstract

BACKGROUND: Cochlear implant (CI) users are affected more than their normal hearing (NH) peers by the negative consequences of background noise on speech understanding. Research has shown that adult CI users can improve their speech recognition in challenging listening environments by using dual-microphone beamformers, such as adaptive directional microphones (ADMs) and wireless remote microphones (RMs). The suitability of these microphone technologies for use in children with CIs is not well-understood nor widely accepted. PURPOSE: To assess the benefit of ADM or RM technology on speech perception in background noise in children and adolescents with cochlear implants (CIs) with no previous or current use of ADM or RM. RESEARCH DESIGN: Mixed, repeated measures design. STUDY SAMPLE: Twenty (20) children, ten (10) CI users (mean age 14.3 yrs) who used Advanced Bionics HiRes90K implants with research Naida processors, and ten (10) NH age-matched controls participated in this prospective study. INTERVENTION: CI users listened with an ear-canal level microphone, T-Mic (TM), an ADM, and a wireless RM at different audio-mixing ratios. Speech understanding with five microphone settings (TM 100%, ADM, RM + TM 50/50, RM + TM 75/25, RM 100%) was evaluated in quiet and in noise. DATA COLLECTION AND ANALYSIS: Speech perception ability was measured using children's spondee words to obtain a speech recognition threshold for 80% accuracy (SRT80%) in 20-talker babble where the listener sat in a sound booth 1 m (3.28') from the target speech (front) and noise (behind) to test five microphone settings (TM 100%, ADM, RM + TM 50/50, RM + TM 75/25, RM 100%). Group performance-intensity functions were computed for each listening condition to show the effects of microphone configuration with respect to signal-to-noise ratio (SNR). A difference score (CI Group minus NH Group) was computed to show the effect of microphone technology at different SNRs relative to NH. Statistical analysis using a repeated-measures analysis of variance evaluated the effects of the microphone configurations on SRT80% and performance at SNRs. Between-groups analysis of variance was used to compare the CI group with the NH group. RESULTS: The speech recognition was significantly poorer for children with CI than children with NH in quiet and in noise when using the TM alone. Adding the ADM or RM provided a significant improvement in speech recognition for the CI group over use of the TM alone in noise (mean dB advantage ranged from 5.8 for ADM to 16 for RM100). When children with CI used the RM75 or RM100 in background babble, speech recognition was not statistically different from the group with NH. CONCLUSION: Speech recognition in noise performance improved with the use of ADM and RM100 or RM75 over TM-only for children with CIs. Alhough children with CI remain at a disadvantage as compared with NH children in quiet and more favorable SNRs, microphone technology can enhance performance for some children with CI to match that of NH peers in contexts with negative SNRs.

Ear & Hearing · 2017

Spatial Release From Masking in Children: Effects of Simulated Unilateral Hearing Loss (opens in a new tab)

Corbin NE, Buss E, Leibold LJ

Abstract

OBJECTIVES: The purpose of this study was twofold: (1) to determine the effect of an acute simulated unilateral hearing loss on children's spatial release from masking in two-talker speech and speech-shaped noise, and (2) to develop a procedure to be used in future studies that will assess spatial release from masking in children who have permanent unilateral hearing loss. There were three main predictions. First, spatial release from masking was expected to be larger in two-talker speech than in speech-shaped noise. Second, simulated unilateral hearing loss was expected to worsen performance in all listening conditions, but particularly in the spatially separated two-talker speech masker. Third, spatial release from masking was expected to be smaller for children than for adults in the two-talker masker. DESIGN: Participants were 12 children (8.7 to 10.9 years) and 11 adults (18.5 to 30.4 years) with normal bilateral hearing. Thresholds for 50%-correct recognition of Bamford-Kowal-Bench sentences were measured adaptively in continuous two-talker speech or speech-shaped noise. Target sentences were always presented from a loudspeaker at 0° azimuth. The masker stimulus was either co-located with the target or spatially separated to +90° or -90° azimuth. Spatial release from masking was quantified as the difference between thresholds obtained when the target and masker were co-located and thresholds obtained when the masker was presented from +90° or -90° azimuth. Testing was completed both with and without a moderate simulated unilateral hearing loss, created with a foam earplug and supra-aural earmuff. A repeated-measures design was used to compare performance between children and adults, and performance in the no-plug and simulated-unilateral-hearing-loss conditions. RESULTS: All listeners benefited from spatial separation of target and masker stimuli on the azimuth plane in the no-plug listening conditions; this benefit was larger in two-talker speech than in speech-shaped noise. In the simulated-unilateral-hearing-loss conditions, a positive spatial release from masking was observed only when the masker was presented ipsilateral to the simulated unilateral hearing loss. In the speech-shaped noise masker, spatial release from masking in the no-plug condition was similar to that obtained when the masker was presented ipsilateral to the simulated unilateral hearing loss. In contrast, in the two-talker speech masker, spatial release from masking in the no-plug condition was much larger than that obtained when the masker was presented ipsilateral to the simulated unilateral hearing loss. When either masker was presented contralateral to the simulated unilateral hearing loss, spatial release from masking was negative. This pattern of results was observed for both children and adults, although children performed more poorly overall. CONCLUSIONS: Children and adults with normal bilateral hearing experience greater spatial release from masking for a two-talker speech than a speech-shaped noise masker. Testing in a two-talker speech masker revealed listening difficulties in the presence of disrupted binaural input that were not observed in a speech-shaped noise masker. This procedure offers promise for the assessment of spatial release from masking in children with permanent unilateral hearing loss.

Hearing Research · 2017

Hyperexcitability of inferior colliculus and acoustic startle reflex with age-related hearing loss (opens in a new tab)

Xiong B, Alkharabsheh A, Manohar S, et al.

Abstract

Chronic tinnitus and hyperacusis often develop with age-related hearing loss presumably due to aberrant neural activity in the central auditory system (CAS) induced by cochlear pathologies. However, the full spectrum of physiological changes that occur in the CAS as a result age-related hearing loss are still poorly understood. To address this issue, neurophysiological measures were obtained from the cochlea and the inferior colliculus (IC) of 2, 6 and 12 month old C57BL/6J mice, a mouse model for early age-related hearing loss. Thresholds of the compound action potentials (CAP) in 6 and 12 month old mice were significantly higher than in 2 month old mice. The sound driven and spontaneous firing rates of IC neurons, recorded with 16 channel electrodes, revealed mean IC thresholds of 22.8 ± 6.5 dB (n = 167) at 2 months, 37.9 ± 6.2 dB (n = 132) at 6 months and 47.1 ± 15.3 dB (n = 151) at 12 months of age consistent with the rise in CAP thresholds. The characteristic frequencies (CF) of IC neurons ranged from 3 to 32 kHz in 2 month old mice; the upper CF ranged decreased to 26 kHz and 16 kHz in 6 and 12 month old mice respectively. The percentage of IC neurons with CFs between 8 and 12 kHz increased from 36.5% in 2 month old mice, to 48.8% and 76.2% in 6 and 12 month old mice, respectively, suggesting a downshift of IC CFs due to the high-frequency hearing loss. The average spontaneous firing rate (SFRs) of all recorded neurons in 2 month old mice was 3.2 ± 2.5 Hz (n = 167). For 6 and 12 month old mice, the SFRs of low CF neurons ( 8 kHz increased to 13.0 ± 15.4 (n = 68) Hz at 6 months of age and then declined to 4.8 ± 7.4 (n = 110) spikes/s at 12 months of age. In addition, sound-evoked activity at suprathreshold levels at 6 months of age was much higher than at 2 and 12 months of age. To evaluate the behavioral consequences of sound evoked hyperactivity in the IC, the amplitude of the acoustic startle reflex was measured at 4, 8 and 16 kHz using narrow band noise bursts. Acoustic startle reflex amplitudes in 6 and 12 month old mice (n = 4) were significantly larger than 2 month old mice (n = 4) at 4 and 8 kHz, but not 16 kHz. The enhanced reflex amplitudes suggest that high-intensity, low-frequency sounds are perceived as louder than normal in 6 and 12 month old mice compared to 2 month olds. The increased spontaneous activity, particularly at 6 months, may be related to tinnitus whereas the increase in sound-evoked activity and startle reflex amplitudes may be related to hyperacusis.

Journal of Communication Disorders · 2017

Listener estimates of talker age in a single-talker, 50-year longitudinal sample (opens in a new tab)

Hunter EJ, Ferguson SH

Abstract

Purpose While many studies have shown that listeners make relatively accurate age judgments from hearing talkers' voices, most have used just one age per talker. The present study evaluated listeners' age estimation abilities for a longitudinal sample: a single talker recorded over nearly five decades. Method We extracted 60 samples from addresses given by a male talker over 48 years. For each sample, listeners gave a direct estimate of his age. We also asked listeners if they could identify the talker, who was known locally, from the recordings. Results While correlations between the talker's chronological age and direct estimates of age were generally strong, the relationship was particularly strong when the talker was older than 68 years, although listeners underestimated chronological age by approximately 5 years. When the talker was between 49 and 68 years, direct age estimates were less accurate and less strongly correlated with chronological age. Additionally, direct age estimates were more accurate when listeners recognized the talker. Conclusions Corroborating cross-sectional studies, our listeners overestimated the talker's age when he was younger and underestimated it when he was older. However, the crossover between overestimation and underestimation, the point where estimated and chronological ages were equal, occurred at a later talker age for this longitudinal study than in previous cross-sectional studies. Additionally, listeners who recognized the talker made more accurate age estimates when the talker's chronological age was near the age where they would have known him. We propose future studies explore the relationship between familiarity and estimated age.

CoDAS · 2017

Hearing in Noise Test (HINT) em portugues brasileiro: criterios de interpretacao de respostas (opens in a new tab)

Melo RDC, Menezes DC, Pacifico FA, et al.

Abstract

Introduction The ability to recognize the sounds of speech enables an efficient communication. This ability must always be considered when communication disorders are evaluated. In this study, sentences of the Hearing in Noise Test (HINT), originally developed in English and adapted to Brazilian Portuguese, were used to evaluate speech recognition in silence and in the presence of noise. Although this test can be an important clinical tool, it is noticed that it has not been used in audiological clinical practice in Brazil. One possible reason is the lack of standardization of some aspects of the test, including the methods adopted to analyze the patient's answers. Purpose The aim of this study was to analyze different judgment criteria of individuals' answers during sentence recognition thresholds measurement using the HINT in Brazilian Portuguese. Methods The study was conducted with 30 young adults (three groups of 10 people), between 18 and 25 years old, of both genders, with normal hearing. HINT sentences were adapted to Brazilian Portuguese and speech recognition thresholds were determined in the presence of noise by using three judgment criteria published in Brazilian literature. A single variation analysis was performed to compare the average threshold between the three groups. The maximum error probability to reject the null hypothesis was 5%. Results The mean and standard deviations of thresholds, respectively, were: 59.90 ± 1.43 dB SPL; 59.60 ± 0.53 dB SPL and 59.95 ± 0.6 dB SPL. There was no statistically significant difference between the means (F = 0.398; p> 0.05). Conclusion Regardless the judging criteria used, results obtained in all groups were equivalent.

Quarterly Journal of Experimental Psychology (2006) · 2017

Visual and acoustic information supporting a happily expressed speech-in-noise advantage (opens in a new tab)

Gordon MS, Ancheta J

Abstract

There was an advantage found for recognizing happily expressed audio and audio-visual speech-in-noise relative to speech spoken with neutral or sad expressions. The advantage of happily expressed speech was explored in a set of visual and acoustic manipulations designed to isolate the potential contributions from each signal. For this research, a replication of previous research with the happily expressed speech advantage was completed with a novel inclusion of a learning paradigm. Additional experiments directly investigated the role of the fundamental frequency of the voice for affect, and the affective facial components with the eyes and mouth. We found that the happily expressed speech advantage persisted despite constraints to the amount of frequency modulation and with distortions to the talker's face. These findings seem largely attributable to the influences of affect on low-level acoustical and articulatory information, with only a very subtle role of approach/withdrawal motivation.

Open Journal of Acoustics · 2017

The Role of Efferent Reduction of Cochlear Compression in the Detection of Tones in Noise (opens in a new tab)

Shaum P. Bhagat, Anusha Yellamsetty

PA5System 3RP2.1HB7Psychoacoustics
Abstract

Stimulation of medial olivocochlear (MOC) efferent neurons reduces basilar membrane (BM) sensitivity and increases the slope of BM input-output (I/O) functions in animal models. Decreased compression of I/O functions associated with activation of MOC efferent neurons may assist in extending the neural response to the tone above that of noise, leading to an improvement in masked thresholds. To evaluate this hypothesis, the distortion-product otoacoustic emission (DPOAE) I/O function, a proxy measure of BM compression, was examined in conditions with presentation of contralateral noise. DPOAE I/O functions were measured at f2 frequencies of 1000 and 2000 Hz in 16 normal-hearing adults. In each subject, estimation of masked thresholds at 1000 and 2000 Hz was provided by a two-interval forced-choice procedure. There were statistically significant associations between DPOAE I/O function slopes and masked tone thresholds at both 1000 and 2000 Hz. At 1000 Hz, individuals with higher DPOAE I/O function slopes exhibited lower masked thresholds. Data at 2000 Hz indicated that individuals with higher masked thresholds exhibited higher DPOAE I/O function slopes. When measured with contralateral noise, DPOAE I/O function slopes were linked to masked thresholds at both frequencies examined in this study. Linearized DPOAE I/O functions presumably reflect linearized BM growth functions under conditions of MOC efferent activation, and this process may have extended the neural response to the signal tone so that it could be more easily heard in the presence of masking noise under certain conditions examined in this study.

Ear & Hearing · 2017

Lateralization of Interaural Level Differences with Multiple Electrode Stimulation in Bilateral Cochlear-Implant Listeners (opens in a new tab)

Olga A. Stakhovskaya, Matthew J. Goupell

PA5System 3RP2.1HB7Psychoacoustics
Abstract

Objective: There is currently no accepted method of mapping bilateral cochlear-implant (BiCI) users to maximize binaural performance, but the current approach of mapping one ear at a time could produce spatial perceptions that are not consistent with a sound’s physical location in space. The goal of this study was to investigate the perceived intracranial lateralization of bilaterally synchronized electrical stimulation with a range of interaural level differences (ILDs) and to determine a method to produce relatively more centered auditory images when provided multielectrode stimulation. Design: Using direct stimulation, lateralization curves were measured in nine BiCI listeners using 1000-pulses per second (pps), 500-msec constant-amplitude pulse trains with ILDs that ranged from −20 to +20 clinical current units (CUs). The stimuli were presented bilaterally at 70 to 80% of the dynamic range on single or multiple electrode pairs. For the multielectrode pairs, the ILD was applied consistently across all the pairs. The lateralization response range and the bias magnitude at 0 CU ILD (i.e., the number of CUs needed to produce a centered auditory image) were computed. Then the levels that elicit a centered auditory image with single-electrode stimulation were used with multielectrode stimulation to determine if this produced fewer significant biases at 0 CU ILD. Lastly, a multichannel ILD processing model was used to predict lateralization for the multielectrode stimulation from the single-electrode stimulation. Results: BiCI listeners often perceived both single- and multielectrode stimulation at 0-CU ILD as not intracranially centered. For single-electrode stimulation, 44% of the lateralization curves had relatively large (≥5 CU) bias magnitudes. For the multielectrode stimulation, 25% of the lateralization curves had large bias magnitudes. After centering the single-electrode pairs, the percentage of multielectrode combinations that produced large biases significantly decreased to only 4% ( p < 0.001, McNemar’s test). The lateralization with multielectrode stimulation was well predicted by a model that used unweighted or weighted average single-electrode lateralization percepts across electrode pairs (87 or 90%, respectively). Conclusion: Current BiCI mapping procedures can produce an inconsistent association between a physical ILD and the perceived location across electrodes for both single- and multielectrode stimulation. Explicit centering of single-electrode pairs using the perceived centered intracranial location almost entirely corrects this problem and such an approach is supported by our understanding and model of across-frequency ILD processing. Such adjustments might be achieved by clinicians using single-electrode binaural comparisons. Binaural abilities, like sound localization and understanding speech in noise, may be improved if these across-electrode perceptual inconsistencies are removed.

Trends in Hearing · 2017

Sensitivity to Angular and Radial Source Movements as a Function of Acoustic Complexity in Normal and Impaired Hearing (opens in a new tab)

Micha Lundbeck, Giso Grimm, Volker Hohmann, … Tobias Neher

Abstract

In contrast to static sounds, spatially dynamic sounds have received little attention in psychoacoustic research so far. This holds true especially for acoustically complex (reverberant, multisource) conditions and impaired hearing. The current study therefore investigated the influence of reverberation and the number of concurrent sound sources on source movement detection in young normal-hearing (YNH) and elderly hearing-impaired (EHI) listeners. A listening environment based on natural environmental sounds was simulated using virtual acoustics and rendered over headphones. Both near-far (‘radial’) and left-right (‘angular’) movements of a frontal target source were considered. The acoustic complexity was varied by adding static lateral distractor sound sources as well as reverberation. Acoustic analyses confirmed the expected changes in stimulus features that are thought to underlie radial and angular source movements under anechoic conditions and suggested a special role of monaural spectral changes under reverberant conditions. Analyses of the detection thresholds showed that, with the exception of the single-source scenarios, the EHI group was less sensitive to source movements than the YNH group, despite adequate stimulus audibility. Adding static sound sources clearly impaired the detectability of angular source movements for the EHI (but not the YNH) group. Reverberation, on the other hand, clearly impaired radial source movement detection for the EHI (but not the YNH) listeners. These results illustrate the feasibility of studying factors related to auditory movement perception with the help of the developed test setup.

The Journal of the Acoustical Society of America · 2017

Use of a glimpsing model to understand the performance of listeners with and without hearing loss in spatialized speech mixtures (opens in a new tab)

Virginia Best, Christine R. Mason, Jayaganesh Swaminathan, … Gerald Kidd

Abstract

In many situations, listeners with sensorineural hearing loss demonstrate reduced spatial release from masking compared to listeners with normal hearing. This deficit is particularly evident in the “symmetric masker” paradigm in which competing talkers are located to either side of a central target talker. However, there is some evidence that reduced target audibility (rather than a spatial deficit per se) under conditions of spatial separation may contribute to the observed deficit. In this study a simple “glimpsing” model (applied separately to each ear) was used to isolate the target information that is potentially available in binaural speech mixtures. Intelligibility of these glimpsed stimuli was then measured directly. Differences between normally hearing and hearing-impaired listeners observed in the natural binaural condition persisted for the glimpsed condition, despite the fact that the task no longer required segregation or spatial processing. This result is consistent with the idea that the performance of listeners with hearing loss in the spatialized mixture was limited by their ability to identify the target speech based on sparse glimpses, possibly as a result of some of those glimpses being inaudible.

Trends in Hearing · 2017

Effect of Energy Equalization on the Intelligibility of Speech in Fluctuating Background Interference for Listeners With Hearing Impairment (opens in a new tab)

Laura A. D’Aquila, Joseph G. Desloge, Charlotte M. Reed, Louis D. Braida

Abstract

The masking release (MR; i.e., better speech recognition in fluctuating compared with continuous noise backgrounds) that is evident for listeners with normal hearing (NH) is generally reduced or absent for listeners with sensorineural hearing impairment (HI). In this study, a real-time signal-processing technique was developed to improve MR in listeners with HI and offer insight into the mechanisms influencing the size of MR. This technique compares short-term and long-term estimates of energy, increases the level of short-term segments whose energy is below the average energy, and normalizes the overall energy of the processed signal to be equivalent to that of the original long-term estimate. This signal-processing algorithm was used to create two types of energy-equalized (EEQ) signals: EEQ1, which operated on the wideband speech plus noise signal, and EEQ4, which operated independently on each of four bands with equal logarithmic width. Consonant identification was tested in backgrounds of continuous and various types of fluctuating speech-shaped Gaussian noise including those with both regularly and irregularly spaced temporal fluctuations. Listeners with HI achieved similar scores for EEQ and the original (unprocessed) stimuli in continuous-noise backgrounds, while superior performance was obtained for the EEQ signals in fluctuating background noises that had regular temporal gaps but not for those with irregularly spaced fluctuations. Thus, in noise backgrounds with regularly spaced temporal fluctuations, the energy-normalized signals led to larger values of MR and higher intelligibility than obtained with unprocessed signals.

Trends in Hearing · 2017

Evaluation of a Frequency-Lowering Algorithm for Adults With High-Frequency Hearing Loss (opens in a new tab)

Marina Salorio-Corbetto, Thomas Baer, Brian C. J. Moore

Abstract

The objective was to determine the effects of a frequency-lowering algorithm (frequency composition, Fcomp) on consonant identification, word-final /s, z/ detection, the intelligibility of sentences in noise, and subjective benefit, for people with high-frequency hearing loss, including people with dead regions (DRs) in the cochlea. A single-blind randomized crossover design was used. Performance with Bernafon Acriva 9 hearing aids was compared with Fcomp off and Fcomp on. Participants wore the hearing aids in each condition in a counterbalanced order. Data were collected after at least 8 weeks of experience with a condition. Outcome measures were audibility, scores from the speech perception tests, and scores from a questionnaire comparing self-perceived hearing ability with Fcomp off and Fcomp on. Ten adults with mild to severe high-frequency hearing loss (seven with extensive DRs, one with patchy or restricted DRs, and two with no DR) were tested. Fcomp improved the audibility of high-frequency sounds for 6 out of 10 participants. There was no overall effect of Fcomp on consonant identification, but the pattern of consonant confusions varied across conditions and participants. For word-final /s, z/ detection, performance was significantly better with Fcomp on than with Fcomp off. Questionnaire scores showed no differences between conditions. In summary, Fcomp improved word-final /s, z/ detection. No benefit was found for the other measures.

Otology & Neurotology · 2017

Comparison of Speech-in-Noise and Localization Benefits in Unilateral Hearing Loss Subjects Using Contralateral Routing of Signal Hearing Aids or Bone-Anchored Implants (opens in a new tab)

Hillary A. Snapp, Fred D. Holt, Xuezhong Liu, Suhrud M. Rajguru

Abstract

Objective: To compare the benefit of wireless contralateral routing of signal (CROS) technology to bone-anchored implant (BAI) technology in monaural listeners. Study Design: Prospective, single-subject. Setting: Tertiary academic referral center. Patients: Adult English speaking subjects using either a CROS hearing aid or BAI as treatment for unilateral severe-profound hearing loss. Interventions: Aided performance utilizing the subjects BAI or CROS hearing device. Main Outcome Measures: Outcome measures included speech-in-noise perception using the QuickSIN ™ (Etymotic Research, Elkgrove Village, IL, 2001) speech-in-noise test and localization ability using narrow and broadband stimuli. Performance was measured in the unaided and aided condition and compared with normal hearing controls. Subjective outcomes measures included the Speech Spatial and Qualities hearing scale and the Glasgow Hearing Aid Benefit Profile. Results: A significant improvement in speech-in-noise performance for monaural listeners ( p < 0.0001) was observed, but there was no improvement in localization ability of either CROS or BAI users. There was no significant difference between CROS and BAI subject groups for either outcome measure. BAI recipients demonstrate higher initial disability and handicap over CROS hearing aid users. No significant difference was observed between treatment groups for subjective measures of post-treatment residual disability or satisfaction. Conclusions: Our data demonstrate that both CROS and BAI systems provide significant benefit for monaural listeners. There is no significant difference between CROS or BAI systems for objective measures of speech-in-noise performance. CROS and BAI hearing devices do not provide any localization benefit in the horizontal plane for monaural listeners and there is no significant difference between systems.

The Journal of Neuroscience · Dec 2016

Selective Neuronal Activation by Cochlear Implant Stimulation in Auditory Cortex of Awake Primate (opens in a new tab)

Luke A. Johnson, Charles C. Della Santina, Xiaoqin Wang

Abstract

Despite the success of cochlear implants (CIs) in human populations, most users perform poorly in noisy environments and music and tonal language perception. How CI devices engage the brain at the single neuron level has remained largely unknown, in particular in the primate brain. By comparing neuronal responses with acoustic and CI stimulation in marmoset monkeys unilaterally implanted with a CI electrode array, we discovered that CI stimulation was surprisingly ineffective at activating many neurons in auditory cortex, particularly in the hemisphere ipsilateral to the CI. Further analyses revealed that the CI-nonresponsive neurons were narrowly tuned to frequency and sound level when probed with acoustic stimuli; such neurons likely play a role in perceptual behaviors requiring fine frequency and level discrimination, tasks that CI users find especially challenging. These findings suggest potential deficits in central auditory processing of CI stimulation and provide important insights into factors responsible for poor CI user performance in a wide range of perceptual tasks. SIGNIFICANCE STATEMENT The cochlear implant (CI) is the most successful neural prosthetic device to date and has restored hearing in hundreds of thousands of deaf individuals worldwide. However, despite its huge successes, CI users still face many perceptual limitations, and the brain mechanisms involved in hearing through CI devices remain poorly understood. By directly comparing single-neuron responses to acoustic and CI stimulation in auditory cortex of awake marmoset monkeys, we discovered that neurons unresponsive to CI stimulation were sharply tuned to frequency and sound level. Our results point out a major deficit in central auditory processing of CI stimulation and provide important insights into mechanisms underlying the poor CI user performance in a wide range of perceptual tasks.