TDT will be closed for Thanksgiving Holiday on November 26th and 27th.

Menu

Auditory Research publications

Hearing research done with TDT systems: auditory neurophysiology, ABR and DPOAE hearing tests, and psychoacoustics.

7,312 papers

Journal of Neurophysiology · 2007

Neural rate and timing cues for detection and discrimination of amplitude-modulated tones in the awake rabbit inferior colliculus (opens in a new tab)

Nelson PC, Carney LH

Abstract

Neural responses to amplitude-modulated (AM) tones in the unanesthetized rabbit inferior colliculus (IC) were studied in an effort to establish explicit relationships between physiological and psychophysical measures of temporal envelope processing. Specifically, responses to variations in modulation depth (m) at the cell's best modulation frequency, with and without modulation maskers, were quantified in terms of average rate and synchronization to the envelope over the entire perceptual dynamic range of depths. Statistically significant variations in the metrics were used to define neural AM detection and discrimination thresholds. Synchrony emerged at modulation depths comparable with psychophysical AM detection sensitivities in some neurons, whereas the lowest rate-based neural thresholds could not account for psychoacoustical thresholds. The majority of rate thresholds (85%) were -10 dB or higher (in 20 log m), and 16% of the population exhibited no systematic dependence of average rate on m. Neural thresholds for AM detection did not decrease systematically at higher SPLs (as observed psychophysically): thresholds remained constant or increased with level for most cells tested at multiple sound-pressure levels (SPLs). At depths higher than the rate-based detection threshold, some rate modulation-depth functions were sufficiently steep with respect to the across-trial variability of the rate to predict depth discrimination thresholds as low as 1 dB (comparable with the psychophysics). Synchrony, on the other hand, did not vary systematically with m in many cells at high modulation depths. A simple computational model was extended to reproduce several features of the modulation frequency and depth dependence of both transient and sustained pure-tone responders.

Neuron · 2007

Neuronal oscillations and multisensory interaction in primary auditory cortex (opens in a new tab)

Lakatos P, Chen CM, O'Connell MN, et al.

Abstract

Recent anatomical, physiological, and neuroimaging findings indicate multisensory convergence at early, putatively unisensory stages of cortical processing. The objective of this study was to confirm somatosensory-auditory interaction in A1 and to define both its physiological mechanisms and its consequences for auditory information processing. Laminar current source density and multiunit activity sampled during multielectrode penetrations of primary auditory area A1 in awake macaques revealed clear somatosensory-auditory interactions, with a novel mechanism: somatosensory inputs appear to reset the phase of ongoing neuronal oscillations, so that accompanying auditory inputs arrive during an ideal, high-excitability phase, and produce amplified neuronal responses. In contrast, responses to auditory inputs arriving during the opposing low-excitability phase tend to be suppressed. Our findings underscore the instrumental role of neuronal oscillations in cortical operations. The timing and laminar profile of the multisensory interactions in A1 indicate that nonspecific thalamic systems may play a key role in the effect.

Neuroscience · 2007

Reorganization of receptive fields following hearing loss in inferior colliculus neurons (opens in a new tab)

Barsz K, Wilson WW, Walton JP

Abstract

We explored frequency and intensity encoding in the inferior colliculus (IC) of the C57 mouse model of sensorineural hearing loss. Consistent with plasticity reported in the IC of other models of hearing loss, frequency response areas (FRAs) in hearing-impaired (HI) mice were broader with fewer high-frequency units than normal-hearing (NH) mice. The broad FRAs recorded from HI mice had lower cutoffs on the low frequency edge of the FRA. Characteristic frequency (CF) and sharpness of tuning (Q10) calculated from the FRA were used to divide the sample into four categories: low-CF sharp-FRA, low-CF broad-FRA, high-CF sharp-FRA, and high-CF broad-FRA units. Rate-intensity functions (RIFs) for CF tones and noise were used to determine the minimum and maximum response counts as well as the sound pressure levels resulting in 10%, 50%, and 90% of the maximum spike count. Tone RIFs of broad FRA units were shifted to the right of tone RIFs of sharp FRA units in both NH and HI mouse IC, regardless of the unit CF. The main effects of hearing loss were seen in the noise RIFs. The low-CF broad-FRA units in HI mice had elevated responses to noise, and the high-CF sharp-FRA units in HI mice had lower maximum rates, as compared with the units recorded from NH mice. These results suggest that, as the IC responds to peripheral hearing loss with changes in the representation of frequency, an altered balance between inhibitory and excitatory inputs to the neurons recorded from the HI mice alters aspects of the units' intensity encoding. This altered balance likely occurs, at least in part, outside of the IC.

Speech Communication · 2007

Subjective comparison and evaluation of speech enhancement algorithms (opens in a new tab)

Hu Y, Loizou PC

Abstract

Making meaningful comparisons between the performance of the various speech enhancement algorithms proposed over the years, has been elusive due to lack of a common speech database, differences in the types of noise used and differences in the testing methodology. To facilitate such comparisons, we report on the development of a noisy speech corpus suitable for evaluation of speech enhancement algorithms. This corpus is subsequently used for the subjective evaluation of 13 speech enhancement methods encompassing four classes of algorithms: spectral subtractive, subspace, statistical-model based and Wiener-type algorithms. The subjective evaluation was performed by Dynastat, Inc. using the ITU-T P.835 methodology designed to evaluate the speech quality along three dimensions: signal distortion, noise distortion and overall quality. This paper reports the results of the subjective tests.

Vision Research · 2007

Feature-based processing of audio-visual synchrony perception revealed by random pulse trains (opens in a new tab)

Fujisaki W, Nishida S

Abstract

Computationally, audio-visual temporal synchrony detection is analogous to visual motion detection in the sense that both solve the correspondence problem. We examined whether audio-visual synchrony detection is mediated by a mechanism similar to low-level motion sensors, by one similar to a higher-level feature matching process, or by both types of mechanisms as in the case of visual motion detection. We found that audio-visual synchrony-asynchrony discrimination for temporally dense random pulse trains was difficult, whereas motion detection is known to be easy for spatially dense random dot patterns (random dot kinematograms) due to the operation of low-level motion sensors. Subsequent experiments further indicated that the temporal limiting factor of audio-visual synchrony discrimination is the temporal density of salient features not the temporal frequency of the stimulus, nor the physical density of the stimulus. These results suggest that audio-visual synchrony perception is based solely on a salient feature matching mechanism similar to that proposed for high-level visual motion detection.

Perception & Psychophysics · 2007

Similarity and categorization of environmental sounds (opens in a new tab)

Gygi B, Kidd GR, Watson CS

Abstract

Four experiments investigated the acoustical correlates of similarity and categorization judgments of environmental sounds. In Experiment 1, similarity ratings were obtained from pairwise comparisons of recordings of 50 environmental sounds. A three-dimensional multidimensional scaling (MDS) solution showed three distinct clusterings of the sounds, which included harmonic sounds, discrete impact sounds, and continuous sounds. Furthermore, sounds from similar sources tended to be in close proximity to each other in the MDS space. The orderings of the sounds on the individual dimensions of the solution were well predicted by linear combinations of acoustic variables, such as harmonicity, amount of silence, and modulation depth. The orderings of sounds also correlated significantly with MDS solutions for similarity ratings of imagined sounds and for imagined sources of sounds, obtained in Experiments 2 and 3--as was the case for free categorization of the 50 sounds (Experiment 4)--although the categorization data were less well predicted by acoustic features than were the similarity data.

Pediatric Research · 2007

Limited Efficacy of Adjuvant Therapy with Dexamethasone in Preventing Hearing Loss Due to Experimental Pneumococcal Meningitis in the Infant Rat (opens in a new tab)

Coimbra RS, Loquet G, Leib SL

System IISigGenABR/DPOAE
Abstract

Sensorineural hearing loss (SNHL) is the most common sequel of bacterial meningitis (BM) and is observed in up to 30% of survivors when the disease is caused by Streptococcus pneumoniae. BM is the single most important origin of acquired SNHL in childhood. Anti-inflammatory dexamethasone holds promises as potential adjuvant therapy to prevent SNHL associated with BM. However, in infant rats, pneumococcal meningitis (PM) increased auditory brainstem response (ABR) thresholds [mean difference = 54 decibels sound pressure level (dB SPL)], measured 3 wk after infection, irrespective to treatment with ceftriaxone plus dexamethasone or ceftriaxone plus saline (p 0.05). These results suggest that more efficient adjuvant therapies are needed to prevent SNHL associated with pediatric PM.

Bioacoustics · 2007

AMPLIFICATION AND SPECTRAL MODIFICATION OF INCOMING VOCALIZATIONS INSIDE BURROWS OF THE FROG EUPSOPHUS ROSEUS (LEPTODACTYLIDAE) (opens in a new tab)

M. PENNA, R. MARQUEZ

Abstract

In previous studies, calling sites of two species of burrowing frogs Eupsophus in southern Chile have been shown to amplify conspecific vocalizations generated externally, thus providing a means to enhance the reception of neighbour's vocalizations in breeding aggregations. In the current study the amplification of vocalizations of Eusophus roseus was investigated to explore the extent of sound enhancement reported previously for two congeneric species. Advertisement calls broadcast through a loudspeaker placed in the vicinity of a burrow, monitored with small microphones, are amplified by up to 14 dB inside cavities relative to outside. The fundamental resonant frequency of burrows, measured with broadcast noise and pure tones, ranges from 345–1335 Hz; however it is not correlated with burrow length. The spectra of incoming calls are altered inside burrows by predominantly increasing the amplitude of lower relative to higher harmonics. The call amplification effect inside burrows of E. roseus parallels the effect reported previously for two congeneric species and reinforces the suggestion that sound enhancement inside calling sites has a widespread effect on signal reception by burrowing animals.

Developmental Cell · 2007

Estrogen-related receptor β/NR3B2 controls epithelial cell fate and endolymph production by the stria vascularis (opens in a new tab)

Jichao Chen, Jeremy Nathans

System 3ABR/DPOAE
Abstract

In the mammalian inner ear, endolymph is produced and resorbed by a complex series of epithelia. We show here that estrogen-related receptor beta (ERR-beta; NR3B2), an orphan nuclear receptor, is specifically expressed in and controls the development of the endolymph-producing cells of the inner ear: the strial marginal cells in the cochlea and the vestibular dark cells in the ampulla and utricle. Nr3b2(-/-) strial marginal cells fail to express multiple ion channel and transporter genes, and they show a partial transformation toward the fate of the immediately adjacent Pendrin-expressing epithelial cells. In genetically mosaic mice, Nr3b2(-/-) strial marginal cells produce secondary alterations in gene expression in the underlying intermediate cells and a local loss of strial capillaries. A systematic comparison of transcripts in the WT versus Nr3b2(-/-) stria vascularis has identified a set of genes that is likely to play a role in the development and/or function of endolymph-producing epithelia.

Audiological Medicine · 2007

In vivo MRI visualization of endolymphatic hydrops induced by keyhole limpet hemocyanin round window immunization (opens in a new tab)

Jing Zou, Ilmari Pyykkö, Börje Bjelke, Esko Toppila

SigGenABR/DPOAE
Abstract

Endolymphatic hydrops is considered one of the principal pathological manifestations of Menière's disease and abnormal immunoreaction may be one of the aetiologies of the disease. To investigate the effect of keyhole limpet hemocyanin (KLH) immunization on cochlear morphology and function in vivo, guinea pigs were inoculated with KLH systemically and received round window membrane delivery (group I). In the control group (group II), KLH was replaced with phosphate buffered saline. In vivo gadolinium diethylenetriaminepentaacetic acidbismethylamide MRI was obtained and compound action potentials were measured. In MRI, evident endolymphatic hydrops was detected in 2 of the 4 animals in group I and blood-endolymph barrier permeability increased in 3 of the 4 animals. The membranous lateral wall and the spiral lamina, in continuation with the organ of Corti, were also demonstrated in the MRI. More than 10 dB hearing loss was found in 2 out of the 4 animals in group I. Neither endolymphatic hydrops nor blood-endolymph barrier permeability change developed in group II.

Journal of Cognitive Neuroscience · 2007

Linking Cortical Spike Pattern Codes to Auditory Perception (opens in a new tab)

Walker KMM, Ahmed B, Schnupp JWH

Abstract

Abstract Neurometric analysis has proven to be a powerful tool for studying links between neural activity and perception, especially in visual and somatosensory cortices, but conventional neurometrics are based on a simplistic rate-coding hypothesis that is clearly at odds with the rich and complex temporal spiking patterns evoked by many natural stimuli. In this study, we investigated the possible relationships between temporal spike pattern codes in the primary auditory cortex (A1) and the perceptual detection of subtle changes in the temporal structure of a natural sound. Using a two-alternative forced-choice oddity task, we measured the ability of human listeners to detect local time reversals in a marmoset twitter call. We also recorded responses of neurons in A1 of anesthetized and awake ferrets to these stimuli, and analyzed these responses using a novel neurometric approach that is sensitive to temporal discharge patterns. We found that although spike count-based neurometrics were inadequate to account for behavioral performance on this auditory task, neurometrics based on the temporal discharge patterns of populations of A1 units closely matched the psychometric performance curve, but only if the spiking patterns were resolved at temporal resolutions of 20 msec or better. These results demonstrate that neurometric discrimination curves can be calculated for temporal spiking patterns, and they suggest that such an extension of previous spike count-based approaches is likely to be essential for understanding the neural correlates of the perception of stimuli with a complex temporal structure.