Hearing Research · 1998
Smurzynski J, Probst R
Abstract
The effects of a consistently disappearing and reappearing spontaneous otoacoustic emission (SOAE) at around 2280 Hz on microstructure for pure tones of varying durations in a 33 year-old woman with normal hearing was studied. The SOAE began to appear after 10-15 min in a quiet test room and increased in level by up to 22 dB over a 30-40-min period. The SOAE was measured every 12 to 15 min. Between measurements, the subject performed a signal detection task for pure tones with total durations varying from 20 to 320 ms. The signal frequencies were within a +/- 30-Hz range relative to the SOAE frequency. For signal durations of 40-320 ms, there was a local dip at the target SOAE frequency when it was either not detectable or its level was lower than -14 dB SPL. Subjective threshold levels were as much as 12 dB better than those obtained when the SOAE was -6 dB SPL or greater. The results suggest that a region of the cochlea with high sensitivity and instability can be put into self-oscillation producing an SOAE, possibly by a change of efferent activity. Hearing threshold is affected possibly due to adaptation or masking.
Hearing Research · 1998
Conlon BJ, Smith DW
Abstract
There is increasing evidence to suggest that free radical generation is central to a variety of pathological processes, including drug toxicity. Studies demonstrating the ability of gentamicin to facilitate the generation of radical species suggest that this process plays an important role in aminoglycoside-induced ototoxicity. Because transition metals, particularly iron, play an important role in the production of free radicals and the generation of reactive oxygen species, we sought to determine whether gentamicin-induced ototoxicity is exacerbated by increases in serum iron levels. To this end, we assessed the effects of supplemental iron administration (2 mg/kg/day and 6 mg/kg/day) on changes in auditory function induced by co-administration of gentamicin (100 mg/kg/day for 30 days). Experiments were carried out on pigmented guinea pigs initially weighing 250-300 g. Changes in cochlear function were characterized as shifts in compound action potential (CAP) thresholds, estimated every third day throughout the treatment period by use of chronic indwelling electrodes implanted at the round window, vertex, and contralateral mastoid. Results showed that animals receiving iron in combination with gentamicin demonstrated a more rapid and profound elevation in CAP thresholds compared with animals receiving gentamicin alone. This effect occurred in a dose-dependent manner. Animals receiving supplemental iron alone maintained normal CAP thresholds throughout the treatment period. There was no statistically significant difference in serum gentamicin levels between groups receiving gentamicin alone or gentamicin plus iron. These results provide further evidence of the recently reported intrinsic role of iron in aminoglycoside ototoxicity, and highlight a potential risk of aminoglycoside administration in patients with elevated serum iron.
Journal of the American Academy of Audiology · Oct 1997
Chertoff ME, Guruprasad SN
Abstract
This study examined the influence of a calibrated transient stimulus on click evoked otoacoustic emissions (CEOAEs). The calibration procedure produced a spectrally uniform stimulus (1-8 kHz) at the plane of the ear probe that was very similar among individuals. However, the calibrated signal reduced the overall level and repeatability of the CEOAE, probably due to the minimization of the energy peak at 2 kHz, which is enhanced in the uncalibrated signal. The amplitude of CEOAEs obtained with the calibrated signal was less variable among individuals compared to CEOAEs obtained with the uncalibrated signal.
Hearing Research · Dec 1996
Boettcher FA, Mills JH, Swerdloff JL, Holley BL
Abstract
The compound action potential (CAP) and the auditory brainstem response (ABR; waves ii and iv) were recorded in young (4-8 month) and aged (33-37 month) gerbils using a paradigm similar to that used in some psychophysical studies of gap detection (a pair of identical low-pass noises separated by a silent gap). Response amplitudes were analyzed in terms of absolute amplitudes and the 'amplitude ratio' (the amplitude of the response to the second noise of a pair divided by that to the first). Response latencies were analyzed in terms of the absolute latencies as well as the 'latency shift' (the latency of the response to the second noise minus that to the first). Response amplitudes were much smaller in the aged subjects for both the first and second stimuli of a pair. There were minimal changes in amplitude ratios across age for both the CAP and ABR. Absolute latencies were similar between groups for the first stimulus of a pair, but latencies to wave iv were much longer for the aged subjects when the gap was short. Thus, the latency shift for the aged group was much longer for wave iv in the aged compared to the young group, but were similar between groups for the CAP or wave ii of the ABR. The results suggest that there may be changes in coding of temporal information in the auditory brainstem of aged gerbils which are not a direct result of abnormal temporal processing in the auditory periphery.
Hearing Research · Sep 1996
Abdala C, Sininger YS, Ekelid M, Zeng FG
Abstract
Distortion product otoacoustic emission (DPOAE) iso-suppression tuning curves (STC) were generated in 15 normal-hearing adults and 16 healthy term-born neonates for three f2 frequencies. The 2f1-f2 DPOAE was elicited using f2/f1 = 1.2, LI = 1.2, LI = 65 and L2 = 50 dB SPL. A suppressor tone was presented at frequencies ranging from 1 octave below to 1/4 octave above f2 and varied in level until DPOAE amplitude was reduced by 6 dB. The suppressor level required for 6 dB suppression was plotted as function of suppressor frequency to generate a DPOAE STC. Forward-masked psychoacoustic tuning curves (PTC) were obtained for three of the adult subjects. Results indicate that DPOAE STCs are stable and show minimal inter- and intra-subject variability. The tip of the STC is consistently centered around the f2 region and STCs are similar in shape, width (Q10) and slope to VIIIth-nerve TCs. PTCs and STCs measured in the same subject showed similar trends, although PTCs had narrower width and steeper slope. Neonatal STCs were recorded at 3000 and 6000 Hz only and were comparable in shape, width and slope to adult STCs. Results suggest: (1) suppression of the 2f1-f2 DPOAE may provide an indirect measure of cochlear frequency resolution in humans and (2) cochlear tuning, and associated active processes in the cochlea, are mature by term birth for at least mid- and high-frequencies. These results provide significant impetus for continued study of DPOAE suppression as a means of evaluating cochlear frequency resolution in humans.
Hearing Research · Sep 1996
Skellett RA, Crist JR, Fallon M, Bobbin RP
Abstract
Chen et al. (1995) recently reported an altered response to the application of ATP in outer hair cells (OHC) isolated from guinea pigs continuously exposed for 10 or 11 days to a 65 dB SPL (A-scale) narrow-band noise (1.1-2.0 kHz). The primary goal of the present study was to test the hypothesis that the continuous low-level noise used by Chen et al. (1995) alters cochlear function. Cubic (2f1-f2) and quadratic (f2-f1) DPOAEs, as well as, the amount of contralateral suppression of DPOAE amplitudes were chosen for study. Responses were recorded in urethane-anesthetized guinea pigs with sectioned middle ear muscles. The animals had either been exposed to the low-level noise for 3 or 11 days or not exposed at all (n = 13 animals per group). Results demonstrate that this noise induces frequency-dependent and very localized reductions in 2f1-f2 DPOAE input/output (I/O) functions. However, the f2-f1 DPOAE I/O functions appear to be insensitive to the noise exposure. No noise-related changes were found in the amount of contralateral suppression between the different exposure groups, with the exception of one unexplainable data point (f2-f1 DPOAE = 0.5 kHz; day 3) where it was reduced. The 2f1-f2 DPOAE amplitude alterations lend support to the conclusions of Chen et al. (1995) that chronic low-level noise exposure induces molecular changes in the OHCs which may, in turn, alter cochlear function.
Proceedings. Biological Sciences · Aug 1996
McAnally KI, Stein JF
Abstract
Developmental dyslexia is generally believed to result from impaired linguistic processing rather than from deficits in low-level sensory function. Challenging this view, we studied the perception of non-verbal acoustic stimuli and low-level auditory evoked potentials in dyslexic adults. Compared with matched controls, dyslexics were selectively impaired in tasks (frequency discrimination and binaural unmasking) which rely on decoding neural discharges phase-locked to the fine structure of the stimulus. Furthermore, this ability to use phase-locking was related to reading ability. In addition, the evoked potential reflecting phase-locked discharges was significantly smaller in dyslexics. These results demonstrate a low-level auditory impairment in dyslexia traceable to the brainstem nuclei.
Audiology · Jul 1995
Fausti SA, Mitchell CR, Frey RH, … Phillips DS
Abstract
An auditory brainstem response method is described for evoking responses to 4 high-frequency (8, 10, 12 and 14 kHz) tonebursts in the same amount of time normally required to obtain responses to single tonebursts. Reliability of responses to high-frequency toneburst stimuli presented in the conventional manner (one at a time) has been previously documented. In the present study, high-frequency tonebursts were presented to 20 normal-hearing subjects singly and in a 4-stimulus sequence. The reliability of resulting responses did not differ significantly between single- and multiple-stimulus test conditions. It is concluded that this sequenced-stimulus concept could be developed for use in serial monitoring of individuals receiving ototoxic agents as well as being broadly applicable to clinical situations in which patients cannot or will not respond voluntarily.
Hearing Research · Dec 1994
Smith DW, Finley CC, van den Honert C, … Konrad KE
Abstract
Estimates of electrical auditory brainstem response (EABR) thresholds are compared with behavioral thresholds for electrical stimulation in the same subject using identical stimuli and electrode configurations. Four cats were behaviorally trained to measure acoustic auditory thresholds using food as a reward in an operant reinforcement paradigm. One of the animals was then implanted, in an otherwise normal ear, with a scaled-UCSF multi-contact electrode array containing four intracochlear electrodes. Three animals were implanted with an electrode array containing eight intracochlear contacts and one extracochlear contact under the temporalis muscle following unilateral cochlear perfusion with 10% neomycin solution. Stimuli for the behavioral studies were single presentations of 200 us/phase biphasic current pulses. For the EABR studies, the same stimulus was presented at a rate of 32/s. In general, for the animal with the four-contact array and two of the three subjects with the eight-contact implant, changes in electrode configuration produced well-differentiated changes in threshold. For these three subjects, comparisons of behavioral and EABR thresholds for the majority of monopolar and bipolar electrode configurations tested showed excellent agreement (r2 = 0.88). Correlations between behavioral and EABR measures in these animals were comparable for bipolar and monopolar arrangements (r2 = 0.88 for bipolar and 0.87 for monopolar). For one subject with the eight-contact electrode, who showed similar monopolar and bipolar electrode behavioral thresholds for all tested electrode spacings or configurations, most EABR thresholds were substantially higher than, and poorly correlated with, behavioral thresholds (r2 = 0.15; r2 = 0.28 for monopolar arrangements, and r2 = 0.12 for bipolar arrangements).
Hearing Research · 1992
Craig A Champlin
Abstract
Auditory steady-state potentials were recorded from the scalp of adult humans. The stimuli were 100-microseconds clicks presented at a rate of 39.1/s. Four stimulus levels were used (-20, 0, 10, and 20 dB SL). The presence or absence of a response was determined by three frequency-domain methods and examiners. The frequency-domain methods were: magnitude-squared coherence (MSC), phase coherence (PC), and magnitude only (MO). The MSC method generally had the highest d' values, indicating that it was the most sensitive method for detecting responses. The hearing threshold predicted by the MSC method was the lowest, and it was within 4 dB of the behaviorally measured threshold for the click stimuli. Further, the amplitude of the response was significantly more variable than its phase, and no relation was found between the variability of the amplitude of the response and the amplitude of the noise. In summary, response detection methods that incorporate phase information (such as MSC and PC) should be chosen over methods which incorporate only amplitude information.
Les Canaux BKCa
C Ferraguto, Y Bouleau, D Dulon