Menu

RZ10X Lux-I/O Processor

LUX Integrated Fiber Photometry Processor

Used in 158 published studies →

The TDT Fiber Photometry platform has been upgraded! Our next-generation RZ10x Fiber Photometry Processors feature new integrated LUX LEDs and Photosensors that plug directly into its front panel. The RZ10x can drive up to six LED light sources and collect fiber photometry data from up to four photosensors simultaneously. This allows for independent control of three-LED imaging from up to two sites or subjects.

TDT’s LUX Integrated Fiber Photometry Processor includes the necessary Synapse software and PO5e computer interface:

  • RZ10x: Deluxe model with 6 LED outputs and 4 sensor inputs

LUX Led and Photosensors The next generation of research tools for calcium imaging and optogenetics

Research Uses

Product Specs

Resources

Publications

  • Fiber Photometry
  • Optogenetic Stimulation
  • Behavioral Studies
  • Electrophysiology
  • 6 LED outputs
  • 4 Photosensor inputs
  • Real-time, lock-in amplification and signal demodulation
  • 24 channels of digital I/O and additional analog I/O
  • Optical ports for synchronized electrophysiology and imaging
  • Synapse software and PO5e PC interface card included

158 published studies used the RZ10X. The newest:

bioRxiv* · Nov 2026

Multi-faceted role of dopamine afferents to the ventral pallidum in reward processing (opens in a new tab)

Williams-Spooner M, Cornish J, Prasad AA

Abstract

The ventral pallidum (VP) is necessary for reward processing and a key node in dopamine (DA) pathways. Yet the direct DA inputs have not been studied during reward learning. Here, we elucidate the role of VP DA in reward processing using circuit tracing, fibre photometry, and behavioural pharmacology in male rats. We show that VP receives both non-DA and DA inputs from the midbrain. During an instrumental reward conditioning paradigm, we characterized VP DA activity using a DA sensor (GRAB_DA1h) across learning, extinction, re-acquisition, and motivational test. Followed by pharmacological manipulation using the DA-antagonist (fluphenazine) in VP to demonstrate a causal role in reward learning and motivation. Together our findings advance the functional contributions of non-canonical mesolimbic DA pathways.

The Journal of Nutrition · Nov 2026

Protein restriction amplifies nucleus accumbens dopamine responses to protein-rich food during operant feeding in male mice (opens in a new tab)

Taghipourbibalan H, Huijgens SW, Volcko KL, McCutcheon JE

Abstract

Background Animals strongly defend protein intake, but how protein status shapes moment-to-moment reward signalling in mesolimbic circuits remains unclear, particularly when the effort required to obtain food varies. Objective We tested whether dietary protein restriction altered nucleus accumbens (NAc) core dopamine signalling when mice worked for food of differing nutritional value in the home cage. Methods Under surgical anaesthesia, male C57BL/6 mice (n=12; ∼12 weeks old at diet initiation) were injected in the NAc core with a virus expressing the fluorescent dopamine sensor GRABDA and implanted with fibre-optic cannulas. In food-access tasks, nose pokes delivered either chow (protein-containing) or sucrose pellets. Across sessions, pellets required either one nose poke (FixedRatio1) or an increasing number (ProgRatio). Fibre photometry measured dopamine release for both pellet types and schedules during three dietary phases: non-restricted diet (NR1; 18% protein), protein-restricted diet (PR; 4%), and restored non-restricted diet (NR2), with 1 week of adaptation between phases. Behavioural and photometry data were analysed using repeated-measures ANOVA. Results Home-cage food intake remained stable, but bodyweight gain fell markedly during PR and partially recovered in NR2 (+10.1% NR1 vs. +1.2% PR vs. +6.0% NR2, p .05). During ProgRatio, dopamine responses at pellet delivery and retrieval did not differ between pellet types in any phase (all ps>.05). Conclusions Protein restriction did not globally amplify reward-related behaviour or dopamine signalling. Instead, it selectively biased NAc dopamine according to the animal's nutritional status, nutrient context, and task demands.

bioRxiv* · Nov 2026

Locus Coeruleus activity correlates with transient elevations in breathing during opioid-induced respiratory depression (opens in a new tab)

Szujewski CC, Soto-Perez J, Yang A, … Garcia AJ

Abstract

A history of use remains a key risk factor for opioid-related overdose deaths in the ongoing opioid epidemic. The locus coeruleus (LC) is the principal source of noradrenergic tone and a site for opioid neuromodulation and tolerance. How a history of opioid use affects LC activity and shapes opioid-induced respiratory depression (OIRD) remains poorly understood. Using plethysmography and fiber photometry, we assessed how fentanyl affects LC activity and OIRD before and after five days of repeat opioid use (ROU). Fentanyl increased the frequency of LC bursts independent of exposure history and was coupled to transient elevations in breathing. LC coupled ventilation (LC-Ve) persisted through ROU. After ROU, OIRD magnitude diverged across mice. Mice developing an adaptive ventilatory response (AVR) showed a smaller OIRD that coincided with improved ventilation outside LC bursts and reduced LC-Ve gain. Mice with the non-adaptive response (NVR) show no improvement in OIRD or ventilation outside LC bursts, resulting in an unchanged reliance on LC-Ve. While LC-Ve reflexively counters OIRD acutely, it may also drive oscillations to destabilize blood gas homeostasis, perpetuating pathophysiology with repeat use. Thus, LC-coupled breathing appears to be a physiological signature of divergent respiratory responses with a history of fentanyl exposure. Impact statement Noradrenergic neurons of the locus coeruleus are activated by fentanyl and coincide with brief surges in breathing during opioid-induced respiratory depression. Reliance on these surges distinguishes mice that fail to develop ventilatory tolerance.

* Preprint: not yet peer reviewed.

Read all 158 papers →

How to cite the RZ10X

Name the model in your Methods so readers can find the equipment you used, for example:

RZ10X Lux-I/O Processor (Tucker-Davis Technologies, Alachua, FL, USA)

Request this product

Enhanced fiber photometry control that now supports:

  • Direct integration of TDT LUX LEDs and Photosensors
  • Current output to modulate standalone LEDs directly
  • Significantly reduced cabling and setup complexity

 

The RZ10 is the best real-time acquisition processor for multi-subject and multi-site fiber photometry recordings. Record multiple demodulated fluorophore responses with TDT’s real-time lock-in amplification to boost the signal-to-noise ratio of your fluorescent signal. The improved signal quality increases the chances of response detection and lowers the number of trials and test subjects required to obtain convincing results.

Read more about TDT’s Fiber Photometry real-time acquisition and recording capabilities.

Interchangeable LEDs and Photosensors

LEDs and photosensors that fit directly into the front panel of the RZ10. You select the combination of LUX LED wavelengths and photosensors that best fit your current research needs, then swap them out for a different set of LED wavelengths later.

TDT’s Lux platform: modular plug-in light sources and photosensors

Hassle-free setup for many Fluorescent wavelengths

TDT has every option to meet your fiber photometry and optogenetic experiment needs. Pick and choose which LED wavelengths to integrate into your experiment with the TDT LUX platform or interface with standalone external LED drivers and LEDs.

TDT’s LUX Platform

Easy experimental setup and execution with Synapse

One Device to house it all

Synapse autodetects all optical hardware connections on the RZ10X to ensure each combination of LED wavelengths and fluorescent responses is correctly matched. The RZ10X integrated LED drivers can deliver high-precision current over a wide dynamic range to drive light power at the microwatt level for fiber photometry or the milliwatt level for optogenetics.

The Synapse drag-and-drop fiber photometry gizmo provides runtime control of all light driver parameters, which includes modulation frequency, waveform amplitude, and DC offset.

Synapse Software

A Single System for all Your Experiments

 

Electrophysiology can make an excellent complement to fiber photometry for the study of neural circuit mechanisms that underly various animal behaviors.  The RZ10X allows for easy integration of fiber photometry and optogenetic stimulation with synchronous electrophysiology and operant box behavioral data all within our easy-to-use Synapse platform. You can also add multiple USB cameras for real-time monitoring of subjects and post hoc behavioral event marking.

The experiment of your dreams is just a few clicks away!

Have a question or would like to see a live demo?  Contact TDT today

What researchers say

More from our customers →

Fewer hours debugging, more hours doing science: hard to beat.

Ross S. Williamson, Ph.D., Assistant ProfessorUniversity of Pittsburgh | www.williamsonlaboratory.com
Read the full testimonial →