TDT will be closed for Thanksgiving Holiday on November 26th and 27th.

Menu

Publications using TDT

More than 10,000 published studies have used TDT systems. Find papers by research area, TDT product or year.

10,510 papers

The Journal of the Acoustical Society of America · 2002

Development of wide-band middle ear transmission in the Mongolian gerbil (opens in a new tab)

Overstreet EH, Ruggero MA

Abstract

UNLABELLED: Stapes vibrations were measured in deeply anesthetized adult and neonatal (ages: 14 to 20 days) Mongolian gerbils. In adult gerbils, the velocity magnitude of stapes responses to tones was approximately constant over the entire frequency range of measurements, 1 to 40 kHz. Response phases referred to pressure near the tympanic membrane varied approximately linearly as a function of increasing stimulus frequency, with a slope corresponding to a group delay of 30 micros. In neonatal gerbils, the sensitivity of stapes responses to tones was lower than in adults, especially at mid-frequencies (e.g., by about 15 dB at 10-20 kHz in gerbils aged 14 days). The input impedance of the adult gerbil cochlea, calculated from stapes vibrations and published measurements of pressure in scala vestibuli near the oval window [E. Olson, J. Acoust. Soc. Am. 103, 3445-3463 (1998)], is principally dissipative at frequencies lower than 10 kHz. CONCLUSIONS: (a) middle-ear vibrations in adult gerbils do not limit the input to the cochlea up to at least 40 kHz, i.e., within 0.5 oct of the high-frequency cutoff of the behavioral audiogram; and (b) the results in both adult and neonatal gerbils are inconsistent with the hypothesis that mass reactance controls high-frequency ossicular vibrations and support the idea that the middle ear functions as a transmission line.

Journal of Neurophysiology · 2002

Immediate changes in tuning of inferior colliculus neurons following acute lesions of cat spiral ganglion (opens in a new tab)

Snyder RL, Sinex DG

Abstract

In previous studies, we demonstrated that acute lesions the spiral ganglion (SG), the cells of origin of the auditory nerve (AN), change the frequency organization of the inferior colliculus central nucleus (ICC) and primary auditory cortex (AI). In those studies, we used a map/re-map approach and recorded the tonotopic organization of neurons before and after restricted SG lesions. In the present study, response areas (RAs) of ICC multi-neuronal clusters were recorded to contralateral and ipsilateral tones after inserting and fixing-in-place tungsten microelectrodes. RAs were recorded from most electrodes before, immediately (within 33-78 min) after, and long (several hours) after restricted mechanical lesions of the ganglion. Each SG lesion produced a "notch" in the tone-evoked compound action potential (CAP) audiogram corresponding to a narrow range of lesion frequencies with elevated thresholds. Responses of contralateral IC neurons, which responded to these lesion frequencies, underwent an elevation in threshold to the lesion frequencies with either no change in sensitivity to other frequencies or with dramatic decreases in threshold to lesion-edge frequencies. These changes in sensitivity produced shifts in characteristic frequency (CF) that could be more than an octave. Thresholds at these new CFs matched the prelesion thresholds of neurons tuned to the lesion-edge frequencies. Responses evoked by ipsilateral tones delivered to the intact ear often underwent complementary changes, i.e., decreased thresholds to lesion frequency tones with little or no change in sensitivity to other frequencies. These results indicate that responses of IC neurons are produced by convergence of auditory information across a wide range of AN fibers and that the acute "plastic" changes reported in our previous studies occur within 1 h of an SG lesion.

Journal of Neurophysiology · 2002

Background noise improves gap detection in tonically inhibited inferior colliculus neurons (opens in a new tab)

Wilson WW, Walton JP

Abstract

Single units in the inferior colliculus (IC) in the C57Bl/6 inbred mouse strain were tested for their temporal processing ability as measured by their minimum gap threshold (MGT), the shortest silent interval in an ongoing white-noise stimulus which a unit could encode. After ascertaining the MGT in quiet, units were re-tested in various levels of background noise. The focus of this report is on two types of tonically responding units found in the IC. Tonically inhibited (TI) units encoded gaps poorly in quiet and low levels of background noise as compared with tonically excited (TE) units. In quiet, the MGTs of TI units were about an order of magnitude longer than the MGTs typical of TE units. Paradoxically, gap encoding was improved in high levels of background noise for TI units. This result is unexpected from the traditional viewpoint that noise necessarily degrades signal processing and is inconsistent with psychophysical observations of diminished speech and gap detection processing in noisy environments. We believe the improved feature detection described here is produced by the adaptation of inhibitory input. Continuous background noise would diminish the inhibitory efficacy of the gap stimulus by increasing the latency to the onset of inhibition and decreasing its duration. This would allow more spontaneous activity to "bleed through" the silent gap, thus signaling its presence. Improved feature detection in background noise resulting from inhibitory adaptation would seem an efficient neural mechanism and one that might be generally useful in other signal detection tasks.

Hearing Research · 2002

Behavioural measurement of level-dependent shifts in the vibration pattern on the basilar membrane (opens in a new tab)

Moore BC, Alcántara JI, Glasberg BR

Abstract

Physiological data suggest that the travelling wave on the basilar membrane evoked by a sinusoid of fixed frequency moves towards the base with increasing level. We describe two psychoacoustic experiments that attempted to provide evidence for and quantify the extent of such a shift in humans. In experiment 1, masking patterns were measured in forward masking using a fixed 6-kHz tone presented at 65 or 85 dB sound pressure level. The threshold for detecting a brief sinusoidal signal was measured as a function of signal frequency for several time delays of the signal relative to the end of the masker. A background noise was included to reduce 'off-frequency listening'. As the signal delay was increased, the signal level at the peaks of the masking patterns decreased and the signal frequency at the peak of the patterns moved progressively towards higher frequencies. The pattern of results was consistent with the idea of a basalward shift of the travelling wave with increasing level. The estimated shift corresponds to about 0.25 octaves for a 40-dB change in level. Experiment 2 also used forward masking. The signal was a 4-kHz tone presented at 10 dB sensation level. For three fixed masker levels (65, 85 and 95 dB), we measured the duration of the gap between the masker and signal required to give 79.4% correct detection of the signal (called the 'gap threshold') as a function of masker frequency; the longer the gap threshold, the more effective is the masker. The gap threshold patterns sometimes showed two peaks. One occurred just below the signal frequency and the frequency at the peak was hardly affected by masker level. The second peak fell at a lower frequency, and this frequency tended to decrease with increasing masker level. The gap threshold patterns tended to spread markedly towards lower frequencies with increasing masker level. The shift with level provides further evidence for a basalward spread of the travelling wave with increasing level.

Neuroscience · 2002

Response of GABAergic cells in the deep mesencephalic nucleus to dopaminergic cell degeneration: an electrophysiological and in situ hybridization study (opens in a new tab)

González-Hernández T, Barroso-Chinea P, Pérez de la Cruz MA, … Rodríguez M

Abstract

The deep mesencephalic nucleus (DMN) is a large midbrain reticular region located between the substantia nigra compacta and the superior colliculus. It contains GABAergic cells that share striatal afferents, thalamic and collicular efferents, as well as neurochemical and electrophysiological similarities, with those of the substantia nigra reticulata. In the present paper we used electrophysiological (firing rate and firing pattern) and morphological (densitometric analysis of in situ hybridization histochemical labeling for glutamic acid decarboxylase (GAD)65 and GAD67 mRNA) techniques, to study the response of DMN GABAergic cells to the degeneration of nigral dopaminergic cells. Our results showed that unilateral dopaminergic cell loss (after injection of 6-hydroxydopamine in the medial forebrain bundle) induces a bilateral and symmetrical increase in both firing rate and GAD67 mRNA levels and a decrease in GAD65 mRNA levels. These findings support the involvement of DMN GABAergic cells in the basal ganglia modifications that follow dopaminergic cell loss, also suggesting its participation in the pathophysiology of Parkinson's disease. The symmetry of effects, together with its recently reported bilateral projections to the thalamus and superior colliculus, suggest that unlike substantia nigra reticulata, DMN is involved in the interhemispheric regulation of basal ganglia, probably keeping their functional symmetry even after asymmetric lesions.

Perception · 2002

Perceived internal depth in rotating and translating objects (opens in a new tab)

Braunstein ML, Sauer CW, Feria CS, Andersen GJ

Abstract

Previous research has indicated that observers use differences between velocities and ratios of velocities to judge the depth within a moving object, although depth cannot in general be determined from these quantities. In four experiments we examined the relative effects of velocity difference and velocity ratio on judged depth within a transparent object that was rotating about a vertical axis and translating horizontally, examined the effects of the velocity difference for pure rotations and pure translations, and examined the effect of the velocity difference for objects that varied in simulated internal depth. Both the velocity difference and the velocity ratio affected judged depth, with difference having the larger effect. The effect of velocity difference was greater for pure rotations than for pure translations. Simulated depth did not affect judged depth unless there was a corresponding change in the projected width of the object. Observers appear to use the velocity difference, the velocity ratio, and the projected width of the object heuristically to judge internal object depth, rather than using image information from which relative depth could potentially be recovered.

The Journal of the Acoustical Society of America · 2002

Speech dynamic range and its effect on cochlear implant performance (opens in a new tab)

Zeng FG, Grant G, Niparko J, … Segel P

Abstract

This study examines optimal conversions of speech sounds to audible electric currents in cochlear-implant listeners. The speech dynamic range was measured for 20 consonants and 12 vowels spoken by five female and five male talkers. Even when the maximal root-mean-square (rms) level was normalized for all phoneme tokens, both broadband and narrow-band acoustic analyses showed an approximately 50-dB distribution of speech envelope levels. Phoneme recognition was also obtained in ten CLARION implant users as a function of the input dynamic range from 10 to 80 dB in 10-dB steps. Acoustic amplitudes within a specified input dynamic range were logarithmically mapped into the 10-20-dB range of electric stimulation typically found in cochlear-implant users. Consistent with acoustic data, the perceptual data showed that a 50-60-dB input dynamic range produced optimal speech recognition in these implant users. The present results indicate that speech dynamic range is much greater than the commonly assumed 30-dB range. A new amplitude mapping strategy, based on envelope distribution differences between consonants and vowels, is proposed to optimize acoustic-to-electric mapping of speech sounds. This new strategy will use a logarithmic map for low-frequency channels and a more compressive map for high-frequency channels, and may improve overall speech recognition for cochlear-implant users.

Physiological Research · 2002

Changes in the acoustically evoked activity in the inferior colliculus of the rat after functional ablation of the auditory cortex (opens in a new tab)

FC Nwabueze-Ogbo, J Popelář, J Syka

Abstract

The role of the cortico-tectal pathways in the processing of auditory signals was investigated by recording the click-evoked responses and extracellular multiple unit activity in the inferior colliculus (IC) after functional ablation of the auditory cortex (AC) by local intracortical application of a sodium channel blocker, tetrodotoxin (TTX). Click-evoked IC responses (IC-ER) and multiple unit activity in response to tone bursts were recorded with implanted electrodes in the IC of rats lightly anaesthetized with xylazine. Neural activity was recorded before and after the application of TTX into the ipsilateral auditory cortex (AC) through three implanted cannulas in a total dose of 30 ng. The functional status of the AC was monitored by recording click-evoked middle latency responses from a ball electrode implanted on the AC. During inactivation of the AC, IC-ER amplitudes were either increased (48 % of the cases), decreased (32 % of the cases) or not evidently changed (20 % of the cases). Corresponding effects were observed in the firing rate of IC neurons. Functional ablation of the AC also resulted in a significant prolongation of the latencies of individual waves of the IC-ER. However, the discharge pattern of the multiple unit responses, response thresholds and tuning were not altered during AC inactivation. IC neural activity recovered within several hours, and maximally during 2 days. The results reveal principles of the interaction of cortico-tectal pathways with IC neuronal activity.

The Journal of Neuroscience · 2002

From spectrum to space: the contribution of level difference cues to spatial receptive fields in the barn owl inferior colliculus (opens in a new tab)

David R. Euston, Terry T. Takahashi

Abstract

Space-specific neurons in the owl's inferior colliculus have spatial receptive fields (RFs) computed from interaural time (ITD) and level (ILD) differences. Because of the shape of the owl's head, these cues vary with frequency in a manner specific for each location. We sought to determine the contribution of ILD to spatial selectivity. We measured the normal spatial receptive fields of space-specific neurons using virtual sound sources (i.e., noises filtered to simulate external sound sources, presented using headphones). The virtual-source filters were then altered so that ITD was fixed while frequency-specific ILDs varied according to location in the usual manner. The resulting “ILD-alone” RF typically revealed a horizontal band of excitation that included the normal RF. Above and below, the neurons were inhibited. Interestingly, the maxima of ILD-alone RFs were generally outside the normal RF, suggesting that space-specific neurons are not optimally tuned to the ILD spectrum occurring at the normal RF location. Congruously, frequency-specific ILD tuning, assessed with tones, better matched the ILDs at the peak of the ILD-alone RF than those at the peak of the normal RF. The firing evoked from the normal RF may thus reflect the balance of excitatory and inhibitory inputs needed to appropriately restrict the receptive field. Frequency-specific ILD tuning curves were combined with measured head-filtering characteristics to predict responses to the frequency-specific ILDs at each location. The predicted ILD-alone RFs, which are based on a simple sum of frequency-specific inputs, accounted for 56% of the variance in our measured ILD-alone RFs.

Stress · 2002

c-fos mRNA induction in acute and chronic audiogenic stress: possible role of the orbitofrontal cortex in habituation (opens in a new tab)

Serge Campeau, David Dolan, Huda Akil, Stanley J. Watson

Abstract

To study putative brain circuits involved in habituation to stress, rats were exposed daily (30 min for 15 days) to an environment in the presence (Chronic) or absence (Acute) of loud noise (105 dB sound pressure level--SPL A Scale). Behavioral and endocrine measures of stress were taken throughout this habituation period, and both measures displayed strong habituation in the Chronic group. All rats were killed immediately after the day 16 exposure, constituting an acute stressor for the Acute group, and regional brain activity was assessed using c-fos mRNA induction with in situ hybridization. Hearing damage could not easily explain these results because additional rats exposed to a similar stress protocol exhibited no changes in auditory brainstem evoked potentials. c-fos mRNA induction in the central auditory system was similar between the Acute and Chronic groups, particularly at lower auditory processing levels, also arguing against a simple reduction in auditory processing in the chronically stressed rats. However, c-fos mRNA expression was reduced in chronically, as compared to acutely, stressed rats in several regions previously implicated in audiogenic stress (lateral septum, bed nucleus of the stria terminalis, some preoptic areas, and the paraventricular hypothalamic nucleus). Interestingly, the orbitofrontal cortex was the only region displaying higher c-fos mRNA induction in the chronically as compared to acutely stressed rats. This region has connections to several stress-responsive areas and may thus be a critical region actively inhibiting stress.

Magnetic Resonance in Medicine · Dec 2001

Simultaneous sampling of event-related BOLD responses in auditory cortex and brainstem (opens in a new tab)

Backes WH, Dijk PV

Abstract

Event-related functional magnetic resonance imaging (fMRI) was applied to investigate blood oxygen level dependent (BOLD) responses in the human auditory system. Auditory fMRI is hindered by the disturbing acoustical noise of echo planar imaging (EPI). A sparse acquisition technique was used in which the delayed hemodynamic response was imaged at discrete sampling time-points after a brief auditory stimulus. Long repetition times (10 heartbeats (HBs)) were used to avoid interactions between the activation due to the sound stimulation and scanner noise. In addition, only a single slice was acquired, to ensure that the scanner noise was minimal in duration and intensity. The image acquisition was triggered by the HB to prevent artifacts from cardiac-related brainstem motion. An image was acquired every 10th HB. Significant hemodynamic BOLD time-course responses were measured from the primary and secondary auditory cortices, as well as the inferior colliculi in the brainstem. No systematic differences were found between the cerebral cortex and the brainstem in terms of activation amplitude or in onset time of the hemodynamic response. Apparently, the slow dynamic nature of the BOLD response signal is similar across spatially separated auditory brain regions, suggesting a corresponding design of vessels and capillaries.

British Journal of Audiology · Dec 2001

Comparison of three procedures for initial fitting of compression hearing aids. I. Experienced users, fitted bilaterally (opens in a new tab)

Moore BC, Alcántara JI, Marriage J

Abstract

We compared the effectiveness of three procedures for the initial fitting of hearing aids with multi-band compression: (1) CAMEQ, which aims to amplify speech so as to give equal loudness per critical band over the frequency range important for speech intelligibility, and to give similar overall loudness to 'normal': (2) CAMREST, which aims to amplify speech so as to restore 'normal' specific loudness patterns, over a wide range of speech levels; (3) DSL I/O, which aims to map the dynamic range of normally hearing people into the reduced dynamic range of hearing-impaired people, with 'full' restoration of audibility. Ten experienced hearing aid users with moderate sensorineural loss were fitted bilaterally with Danalogic 163D digital hearing aids, using each procedure in turn; the order was counterbalanced across subjects. The fitting required specification of gains for input levels of 55 and 80 dB SPL at six centre frequencies. Real-ear measurements were made to ensure that target gains were reached (+/-3 dB). Immediately after fitting with a given procedure, and one week after fitting, the gains were adjusted when required by the minimum amount necessary to achieve acceptable fittings. The amount of adjustment required provides one measure of the adequacy of the initial fitting. On average, the adjustments were smallest for the CAMEQ procedure. The gain changes were slightly larger for the CAMREST procedure and were largest of all for DSL I/O. For the latter, the gain changes were mostly negative, especially for high frequencies and the higher input level. This indicates that the DSL I/O procedure prescribes more high-frequency gain than is preferred by adult users. After these gain adjustments, users wore the aids for at least three weeks before filling out the APHAB questionnaire and taking part in laboratory measurements of the speech reception threshold (SRT) for sentences in quiet and in steady and fluctuating background noise at levels of 60 and 75 dB SPL. Following these tests, the hearing aids were re-fitted with the next procedure. The scores on the APHAB test and the SRTs did not differ significantly for the three procedures. We conclude that the CAMEQ and CAMREST procedures provide more appropriate initial fittings than DSL I/O.

Hearing Research · Dec 2001

Simultaneous exposure to ethyl benzene and noise: synergistic effects on outer hair cells (opens in a new tab)

Cappaert NL, Klis SF, Muijser H, … Smoorenburg GF

Abstract

The effects on hearing of simultaneous exposure to the ototoxic organic solvent ethyl benzene and broad-band noise were evaluated in rats. The effects of three ethyl benzene concentrations (0, 300 or 400 ppm) and three noise levels (95 or 105 dB(lin) SPL or background noise at 65 dB(lin) SPL) and all their combinations were investigated for a 5 day exposure at 8 h/day. Distortion product otoacoustic emissions and compound action potentials were affected after 105 dB noise alone, and after 105 dB noise in combination with ethyl benzene (300 and 400 ppm). However, the amount of loss for these combinations did not exceed the loss for 105 dB noise alone. Outer hair cell (OHC) loss after exposure to 300 ppm ethyl benzene was located in the third row of OHCs. At 400 ppm, the loss spread out to the second and first row of OHCs. Noise alone hardly affected the OHC counts except for a minor loss in the first row of OHCs after 105 dB SPL. Noise at 105 dB in combination with ethyl benzene at 300 and 400 ppm, however, showed OHC loss greater than the sum of the losses induced by noise and ethyl benzene alone.

Journal of Voice · Dec 2001

Discrimination functions: can they be used to classify singing voices? (opens in a new tab)

Erickson ML, Perry S, Handel S

Abstract

Researchers long have searched for invariant acoustic features that can be used to identify singing voice categories or even individual singers. Few researchers have examined how listeners perceive singing voice categories or individual voices. Timbre, the most studied perceptual dimension of the singing voice, is generally believed to vary systematically between singing voice categories but is often assumed to be invariant with an individual singer. To test this assumption, 2 mezzo-sopranos and 2 sopranos were recorded singing the vowel /a/ on the pitches A3, C4, G4, B4, F5, and A5. Trials of three stimuli were constructed. Two of the three stimuli in each trial were produced by the same singer at two different pitches (X1 and X2), while the third stimulus was produced by a different singer (Y). Three X1X2 conditions were created: (1) G4, B4; (2) C4, F5; and (3) A3, A5. For each singer and each condition, Y was varied across the three remaining singers and across all six pitches. Experienced and inexperienced listeners were asked to identify which stimulus was produced by the "odd" person. The ability to correctly choose the odd person varied greatly depending on pitch factors, suggesting that the traditional concept of an invariant timbre associated with a singer is inaccurate and that vocal timbre must be conceptualized in terms of transformations in perceived quality that occur across an individual singer's range and/or registers.

The Journal of Physiology · Dec 2001

The temporal representation of the delay of iterated rippled noise in the ventral cochlear nucleus of the guinea-pig (opens in a new tab)

Winter IM, Wiegrebe L, Patterson RD

Abstract

1. We have examined the temporal discharge patterns of single units from the ventral cochlear nucleus (VCN) of anaesthetized guinea-pigs in response to iterated rippled noise (IRN). The pitch range evoked by the stimuli was from 32 to 1000 Hz. 2. Single units were classified into four groups using existing classification schemes: primary-like (PL), onset (O), sustained chopper (CS) and transient chopper (CT). For all unit types the delay of the IRN stimuli was well represented in the all-order interspike interval histograms (ISIHs). 3. A subset of the onset units (onset-chopper, OC) showed a clear preference for some delays of the IRN in their first-order interval statistics. We describe this delay preference as 'periodicity tuning'. The delay at which the pitch estimate was at its maximum was designated its best periodicity. The range of best periodicities for OC units was 3.75-13 ms (between 77 and 267 Hz). 4. The other unit types also showed enhancement of the first-order interval statistics at the delay of the IRN. The range of best periodicities was 1.4-8.8 ms (113-714 Hz) for the CT group, 2.25-10.8 ms (93-444 Hz) for the CS group and 0.5-4.6 ms (217-2000 Hz) for the PL group. 5. The correlation between the maximum interval enhancement observed in response to the IRN stimuli and the peak in the first-order ISIH in response to white noise was 0.81 for OC units, 0.72 for CS units, 0.44 for CT units and -0.15 for PL units. 6. These results demonstrate that all unit types in the VCN can enhance the representation of the delay of IRN using first-order interspike intervals (ISIs) over a range of periodicities. CS and OC units show the greatest range of best periodicities and they are well-suited to encode the delay of IRN in their first-order ISIs for a wide range of pitches.

Journal of Neurophysiology · Dec 2001

Mechanisms underlying the sensitivity of neurons in the lateral superior olive to interaural intensity differences (opens in a new tab)

Irvine DR, Park VN, McCormick L

Abstract

The initial processing of interaural intensity differences (IIDs), the major cue to the azimuthal location of high-frequency sounds in mammals, is carried out by neurons in the lateral superior olivary nucleus (LSO) that receive excitatory input from the ipsilateral ear and inhibitory input from the contralateral ear (IE neurons). The "latency" hypothesis asserts that it is the effects of intensity differences on the latency, and hence the relative timing, of the synaptic inputs to these neurons that is the basis of their sensitivity to IIDs, while other models assign the major role to changes in the relative amplitude of the inputs. To test the latency hypothesis and to determine the contributions of changes in the relative timing and amplitude of synaptic inputs to the IID sensitivity of LSO neurons, a method was developed of generating sets of stimuli that produced either the same changes in the relative timing of inputs without any change in their amplitude (equivalent interaural time difference stimuli) or the same differences in amplitude without any difference in timing (delay-cancelled IID stimuli) as a given range of IIDs. Data were obtained from a sample of IE neurons in the LSO of anesthetized rats using these stimulus paradigms and click and tone-burst stimuli. For click stimuli, the IID sensitivity of a small proportion of neurons was explained entirely by sensitivity to differences in input timing, but the sensitivity of most neurons reflected either sensitivity to the relative amplitude of inputs or to the joint operation of both factors. In neurons whose sensitivity was tested at a number of different absolute sound pressure levels (SPLs), the relative contributions of the two factors tended to differ at different SPLs. The IID sensitivity of onset responses to tone stimuli could be classified into the same three categories but was explained for a larger proportion of neurons by sensitivity to differences in input timing. The IID sensitivity of the late response component of neurons with sustained responses to tones in all cases reflected sensitivity to the relative amplitude of the inputs. The results confirm the contribution of changes in latency produced by intensity changes to the IID sensitivity of the onset responses of many IE neurons in LSO but require rejection of the strong form of the latency hypothesis, which asserts that this factor alone accounts for such sensitivity.

Journal of Neurophysiology · Dec 2001

Consonance and dissonance of musical chords: neural correlates in auditory cortex of monkeys and humans (opens in a new tab)

Fishman YI, Volkov IO, Noh MD, … Steinschneider M

Abstract

Some musical chords sound pleasant, or consonant, while others sound unpleasant, or dissonant. Helmholtz's psychoacoustic theory of consonance and dissonance attributes the perception of dissonance to the sensation of "beats" and "roughness" caused by interactions in the auditory periphery between adjacent partials of complex tones comprising a musical chord. Conversely, consonance is characterized by the relative absence of beats and roughness. Physiological studies in monkeys suggest that roughness may be represented in primary auditory cortex (A1) by oscillatory neuronal ensemble responses phase-locked to the amplitude-modulated temporal envelope of complex sounds. However, it remains unknown whether phase-locked responses also underlie the representation of dissonance in auditory cortex. In the present study, responses evoked by musical chords with varying degrees of consonance and dissonance were recorded in A1 of awake macaques and evaluated using auditory-evoked potential (AEP), multiunit activity (MUA), and current-source density (CSD) techniques. In parallel studies, intracranial AEPs evoked by the same musical chords were recorded directly from the auditory cortex of two human subjects undergoing surgical evaluation for medically intractable epilepsy. Chords were composed of two simultaneous harmonic complex tones. The magnitude of oscillatory phase-locked activity in A1 of the monkey correlates with the perceived dissonance of the musical chords. Responses evoked by dissonant chords, such as minor and major seconds, display oscillations phase-locked to the predicted difference frequencies, whereas responses evoked by consonant chords, such as octaves and perfect fifths, display little or no phase-locked activity. AEPs recorded in Heschl's gyrus display strikingly similar oscillatory patterns to those observed in monkey A1, with dissonant chords eliciting greater phase-locked activity than consonant chords. In contrast to recordings in Heschl's gyrus, AEPs recorded in the planum temporale do not display significant phase-locked activity, suggesting functional differentiation of auditory cortical regions in humans. These findings support the relevance of synchronous phase-locked neural ensemble activity in A1 for the physiological representation of sensory dissonance in humans and highlight the merits of complementary monkey/human studies in the investigation of neural substrates underlying auditory perception.

British Journal of Audiology · Dec 2001

Effects of slow-and fast-acting compression on the detection of gaps in narrow bands of noise (opens in a new tab)

Moore BC, Glasberg BR, Alcántara JI, … Kuehnel V

Abstract

The inherent amplitude fluctuations in narrow bands of noise may limit the ability to detect gaps in the noise; 'dips' in the noise may be confused with the gap to be detected. For people with cochlear hearing loss, loudness recruitment may effectively magnify the fluctuations and this could partly account for the reduced ability to detect gaps in noise bands that is usually found for such people. Previously, we tested these ideas by processing the envelopes of noise bands to alter the amount of envelope fluctuation. We showed that instantaneous compression, implemented via processing of the Hilbert envelope, led to smaller (that is, better) gap detection thresholds for subjects with cochlear hearing loss. In the present experiment, we determined whether fast-acting compression of the type sometimes used in hearing aids could also lead to improved gap detection. A behind-the-ear (BTE) digital hearing aid was programmed to implement multi-band compression, either fast-acting or slow-acting (control condition). A reference condition using unaided listening was also used. Stimuli were delivered via an earphone placed over the hearing aid. Overall stimulus levels at the output of the hearing aid were similar across conditions. Thresholds for detecting gaps in noise bands centred at 4 kHz were measured as a function of noise bandwidth (10-500 Hz). To prevent the detection of spectral changes introduced by the gap, stimuli were presented in a broad-band background noise. Three normally hearing subjects and three subjects with bilateral cochlear hearing loss were tested. Gap thresholds varied non-monotonically with noise bandwidth, being maximal around 50 Hz. Gap thresholds were generally higher for the hearing-impaired than for the normally hearing subjects. For the latter, gap thresholds were similar for the three conditions. For the hearing-impaired subjects, gap thresholds were similar for the unaided condition and the condition using slow compression. However, fast compression led to smaller gap thresholds, especially for noise bandwidths up to 50 Hz. The results show that fast compression can improve the ability of hearing-impaired subjects to detect gaps in sounds with slowly fluctuating envelopes.

The Journal of Neuroscience · Dec 2001

Cochlear and neural delays for coincidence detection in owls (opens in a new tab)

José Luis Peña, Svenja Viete, Kazuo Funabiki, … Masakazu Konishi

Abstract

The auditory system uses delay lines and coincidence detection to measure the interaural time difference (ITD). Both axons and the cochlea could provide such delays. The stereausis theory assumes that differences in wave propagation time along the basilar membrane can provide the necessary delays, if the coincidence detectors receive input from fibers innervating different loci on the left and right basilar membranes. If this hypothesis were true, the left and right inputs to coincidence detectors should differ in their frequency tuning. The owl's nucleus laminaris contains coincidence detector neurons that receive input from the left and right cochlear nuclei. Monaural frequency-tuning curves of nucleus laminaris neurons showed small interaural differences. In addition, their preferred ITDs were not correlated with the interaural frequency mismatches. Instead, the preferred ITD of the neuron agrees with that predicted from the distribution of axonal delays. Thus, there is no need to invoke mechanisms other than neural delays to explain the detection of ITDs by the barn owl's laminaris neurons.

Proceedings of the National Academy of Sciences of the United States of America · Nov 2001

Dynamic control of auditory activity during sleep: correlation between song response and EEG (opens in a new tab)

Nick TA, Konishi M

Abstract

The song nucleus high vocal center (HVC) sends neural signals for song production and receives auditory input. By using electroencephalography (EEG) to objectively identify wake/sleep state, we show that HVC auditory responses change with physiological states. Comparison of EEG and HVC records revealed that HVC response to auditory stimuli is greatest during slow-wave sleep. During slow-wave sleep, HVC neurons responded preferentially to the bird's own song. Strikingly, both spontaneous and forced waking during sleep caused HVC auditory responses to cease within milliseconds of an EEG-measured state change. State-dependent phenomena in downstream nuclei, such as robustus archistriatalis, are likely to be derivatives of those in HVC.