TDT will be closed for Thanksgiving Holiday on November 26th and 27th.

Menu

LFP publications

Local field potential recordings made with TDT systems.

858 papers

Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference · 2008

The effects of interictal spikes on single neuron firing patterns in the hippocampus during the development of temporal lobe epilepsy (opens in a new tab)

Yan W, Mitzelfelt JD, Principe JC, Sanchez JC

Abstract

The interictal spikes (IS) are characteristic signatures of epileptic tissue, and relevant in presurgical evaluation of epilepsy. However, the mechanism and effects of IS remain unclear. In this study, we examined the relationship between IS and single neuron firing patterns, using an epileptic rat with temporal lobe epilepsy (TLE). We investigated the firing of interneurons and pyramidal cells in the CA3 region of the hippocampus. The results show that IS are associated with decreased single neuron firing rates compared with IS-free epochs. Furthermore, the paroxysmal interictal-spiking patterns are associated with sustained decrease in single neuron firing rates. We also found that IS stopped as approaching to seizures. These results demonstrate that IS might be responsible for the development of TLE and ictal events by changing the firing patterns of hippocampal neurons.

The Journal of Neuroscience · Aug 2007

Spatially distinct functional output regions within the central nucleus of the inferior colliculus: implications for an auditory midbrain implant (opens in a new tab)

Lim HH, Anderson DJ

Abstract

The inferior colliculus central nucleus (ICC) has potential as a new site for an auditory prosthesis [i.e., auditory midbrain implant (AMI)] for deaf patients who cannot benefit from cochlear implants (CIs). We have previously shown that ICC stimulation achieves lower thresholds, greater dynamic ranges, and more localized, frequency-specific primary auditory cortex (A1) activation than CI stimulation. However, we also observed that stimulation location along the caudorostral (isofrequency) dimension of the ICC affects thresholds and frequency specificity in A1, suggesting possible differences in functional (output) organization within the ICC. In this study, we electrically stimulated different regions along the isofrequency laminas of the ICC and recorded the corresponding A1 activity in ketamine-anesthetized guinea pigs using multisite probes to systematically assess ICC stimulation location effects. Our results indicate that stimulation of more rostral and somewhat ventral regions within an ICC lamina achieves lower thresholds, smaller discriminable level steps, and larger evoked potentials in A1. We also observed longer first spike latencies, which correlated with reduced spiking precision, when stimulating in more caudal and dorsal ICC regions. These findings suggest that at least two spatially distinct functional output regions exist along an ICC lamina: a caudal-dorsal region and a rostral-ventral region. The AMI will be implanted along the tonotopic axis of the ICC to achieve frequency-specific activation. However, stimulation location along the ICC laminas affects response properties that have shown to be important for speech perception performance, and needs to be considered when implanting future AMI patients.

Hearing Research · Feb 2007

Direct comparison between properties of adaptation of the auditory nerve and the ventral cochlear nucleus in response to repetitive clicks (opens in a new tab)

Meyer K, Rouiller EM, Loquet G

Abstract

The present study was designed to complete two previous reports [Loquet, G., Rouiller, E.M., 2002. Neural adaptation to pulsatile acoustical stimulation in the cochlear nucleus of the rat. Hear. Res. 171, 72-81; Loquet, G., Meyer, K., Rouiller, E.M., 2003. Effects of intensity of repetitive acoustic stimuli on neural adaptation in the ventral cochlear nucleus of the rat. Exp. Brain Res. 153, 436-442] on neural adaptation properties in the auditory system of the rat. Again, auditory near-field evoked potentials (ANEPs) were recorded in response to 250-ms trains of clicks from an electrode chronically implanted in the ventral cochlear nucleus (VCN). Up to now, our interest had focused on the adaptive behavior of the first one (N1) of the two negative ANEP components. A re-examination of our data for the second negative component (N2) was now undertaken. Results show that the adaptation time course observed for N2 displayed the same three-stage pattern previously reported for N1. Similarly, adaptation became more pronounced and occurred faster as stimulus intensity and/or repetition rate were increased. Based on latency data which suggest N1 and N2 to be mainly due to the activity of auditory-nerve (AN) fibers and cochlear nucleus neurons, respectively, it was concluded that neural adaptation assessed by gross-potentials was similar in the AN and VCN. This finding is meaningful in the context of our search to restore normal adaptation phenomena via electro-auditory hearing with an auditory brainstem implant on the same lines as our work in cochlear implants.

Acta Oto-Laryngologica · Feb 2007

General anesthesia changes gap-evoked auditory responses in guinea pigs (opens in a new tab)

Feng Y, Wang J, Yin S

Abstract

Conclusion General anesthesia induced by sodium pentobarbital reduces temporal resolution as represented by an increase in the threshold of gap-evoked auditory responses in guinea pigs. Objectives To explore the potential impact of general anesthesia by sodium pentobarbital (PB), a common anesthetic used in animal research, on gap-evoked responses. Materials and methods The evoked potentials in response to gaps formed by bursts of broadband noise were recorded from electrodes implanted in the inferior colliculus (IC) and the auditory cortex (AC) of guinea pigs. The gap responses were compared in three conditions: unanesthetized and anesthetized with two doses of sodium pentobarbital (40 mg/kg and 20 mg/kg). Results PB increased the gap response thresholds, especially when applied at the higher dose. The threshold shift induced by PB was greater in the AC than in the IC. In addition, the higher dose of PB significantly increased the gap response latency in both IC and AC, and decreased response amplitude in IC only.

Acta Oto-laryngologica. Supplementum · Dec 2006

Salicylate-and quinine-induced tinnitus and effects of memantine (opens in a new tab)

Lobarinas E, Yang G, Sun W, … Salvi R

MW16LFP
Abstract

Conclusion Memantine, an antiglutamatergic drug, has been proposed as a treatment for tinnitus. Objectives The purpose of this study was to determine if memantine would prevent salicylate-induced tinnitus. Local field potentials were also recorded from auditory cortex to determine what effect salicylate, memantine, and the combination of both drugs would have on evoked potential amplitudes. Materials and methods Schedule induced polydipsia-avoidance conditioning was used to identify the doses of salicylate or quinine that reliably induced tinnitus in rats. Rats were trained to lick for water during quiet intervals and avoid licking during sound intervals. Results Rats injected with saline or a low dose of sodium salicylate or quinine failed to develop tinnitus-like behaviors. However, high doses of salicylate (150-300 mg/kg/day) or quinine (100-150 mg/kg/day) greatly reduced licks-in-quiet, behavior consistent with the presence of tinnitus. Licks-in-quiet increased slightly when memantine (1.5 or 3 mg/kg/day) was co-administered with salicylate; however, the effect was not statistically significant or dose-dependent. These results indicate that memantine does not completely suppress salicylate-induced tinnitus. Cortical auditory evoked potential amplitude increased after salicylate treatment; co-administration of memantine failed to block this salicylate-induced increase.

Journal of the Association for Research in Otolaryngology · Nov 2006

Electrophysiological validation of a human prototype auditory midbrain implant in a guinea pig model (opens in a new tab)

Lenarz M, Lim HH, Patrick JF, et al.

Abstract

The auditory midbrain implant (AMI) is a new treatment for hearing restoration in patients with neural deafness or surgically inaccessible cochleae who cannot benefit from cochlear implants (CI). This includes neurofibromatosis type II (NF2) patients who, due to development and/or removal of vestibular schwannomas, usually experience complete damage of their auditory nerves. Although the auditory brainstem implant (ABI) provides sound awareness and aids lip-reading capabilities for these NF2 patients, it generally only achieves hearing performance levels comparable with a single-channel CI. In collaboration with Cochlear Ltd. (Lane Cove, Australia), we developed a human prototype AMI, which is designed for electrical stimulation along the well-defined tonotopic gradient of the inferior colliculus central nucleus (ICC). Considering that better speech perception and hearing performance has been correlated with a greater number of discriminable frequency channels of information available, the ability of the AMI to effectively activate discrete frequency regions within the ICC may enable better hearing performance than achieved by the ABI. Therefore, the goal of this study was to investigate if our AMI array could achieve low-threshold, frequency-specific activation within the ICC, and whether the levels for ICC activation via AMI stimulation were within safe limits for human application. We electrically stimulated different frequency regions within the ICC via the AMI array and recorded the corresponding neural activity in the primary auditory cortex (A1) using a multisite silicon probe in ketamine-anesthetized guinea pigs. Based on our results, AMI stimulation achieves lower thresholds and more localized, frequency-specific activation than CI stimulation. Furthermore, AMI stimulation achieves cortical activation with current levels that are within safe limits for central nervous system stimulation. This study confirms that our AMI design is sufficient for ensuring safe and effective activation of the ICC, and warrants further studies to translate the AMI into clinical application.

International Journal of Audiology · Sep 2006

The effect of gap-marker spectrum on gap-evoked auditory response from the inferior colliculus and auditory cortex of guinea pigs (opens in a new tab)

Wang J, Fenga Y, Yin S

Abstract

The objective of this study is to verify the effects of gap marker spectrum on gap-evoked auditory responses. The gap-evoked potentials were recorded using electrodes implanted in the inferior colliculus (IC) and auditory cortex (AC) of guinea pigs. The gap markers were noise bursts in four frequency bands (500-8,000 Hz, 500-16,000 Hz, 500-32,000 Hz, and 16,000-32,000 Hz), and were tested at three sound levels. The onset response to the post-gap marker was measured to obtain the gap response threshold, and to establish input-output functions for latency and amplitude. Similar to previous behavioural studies, it was found that the gap-response threshold decreased with increasing marker bandwidth. This change was more significant at the cortical level in which the averaged gap-threshold decreased by approximately 2 ms with the bandwidth change. However, the gap threshold in the high frequency region (16,000-32,000 Hz) was comparable to that of the low frequency region (500-16,000 Hz). These results suggest that the total bandwidth of all auditory channels that are recruited determine the temporal resolution measured in gap-evoked potentials.

Neuroscience Letters · May 2006

Isoflurane disrupts anterio-posterior phase synchronization of flash-induced field potentials in the rat (opens in a new tab)

Imas OA, Ropella KM, Wood JD, Hudetz AG

Abstract

Consciousness presumes a set of integrated functions such as sensory processing, attention, and interpretation, and may depend upon both local and long-range phase synchronization of neuronal activity in cerebral cortex. Here we investigated whether volatile anesthetic isoflurane at concentrations that produce loss of consciousness (LOC) disrupts long-range anterio-posterior and local anterior synchronization of neuronal activity in the rat. In six rats, deep electrodes were chronically implanted in the primary visual cortex (V1) and in two areas of the motor cortex (M1 and M2) for recording of intracortical event-related potentials (ERP). Thirty discrete flashes were presented at random interstimulus intervals of 15-45 s, and ERPs were recorded at stepwise increasing isoflurane concentrations of 0-1.1%. Neuronal synchronization was estimated using wavelet coherence computed from the ERP data band-pass filtered at 5-50 Hz. We found that (1) in the waking state, long-range anterio-posterior coherence in 5-25 Hz and 25-50 Hz frequency bands was significantly higher than local anterior coherence; (2) anterio-posterior coherence in both 5-25 Hz and 26-50 Hz bands was significantly reduced by isoflurane in a concentration-dependent manner; (3) local anterior coherence was not affected by isoflurane at any of the concentrations studied. These findings suggest that a disruption of long-range anterio-posterior rather than local anterior synchronization of neuronal activity precedes the anesthetic-induced loss of consciousness.

Conference Proceedings : ... Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual Conference · 2006

A comparison of neural feature extraction methods for brain-machine interfaces (opens in a new tab)

Gilmour TP, Krishnan L, Gaumond RP, Clement RS

Abstract

Brain-machine interferes (BMIs) have shown promise in augmenting people's control of their surroundings, especially for those suffering from paralysis due to neurological disorders. This paper describes an experiment using the rodent model to explore information available in neural signals recorded from chronically implanted intracortical microelectrode arrays. In offline experiments, a number of neural feature extraction methods were utilized to obtain neural activity vectors (NAVs) describing the activity of the underlying neural population while rats performed a discrimination task. The methods evaluated included standard techniques such as binned spike rates and local field potential spectra as well as more novel approaches including matched-filter energy, raw signal spectra, and an autocorrelation energy measure (AEM) approach. Support vector machines (SVMs) were trained offline to classify left from right going movements by utilizing features contained in the NAVs obtained by the different methods. Each method was evaluated for accuracy and robustness. Results show that most algorithms worked well for decoding neural signals both during and prior to movement, with spectral methods providing the best stability.

NeuroImage · Aug 2004

Haemodynamic responses to sensory stimulation are enhanced following acute cocaine administration (opens in a new tab)

Devonshire IM, Berwick J, Jones M, … Mayhew JE

MedusaLFP
Abstract

Cocaine enhances neural activity in response to sensory stimulation, an effect that may play a role in the development of drug craving. However, cocaine-induced sensory enhancement may be difficult to study in humans using neuroimaging if the global increases in baseline haemodynamic parameters, which cocaine produces, interfere with the ability of enhanced sensory-related neural activity to lead to enhanced haemodynamic responses. To investigate the effect of cocaine-induced baseline haemodynamic changes on sensory-related haemodynamic (and electrophysiological) responses, field potential (FP) and haemodynamic responses (obtained using optical imaging spectroscopy and laser-Doppler flowmetry) in the barrel cortex of the anaesthetised rat were measured during mechanical whisker stimulation following cocaine (0.5 mg/kg) or saline administration. During cocaine infusion, the relationship between blood flow and volume transiently decoupled. Following this, cocaine caused large baseline increases in blood flow (133%) and volume (33%), which peaked after approximately 6 min and approached normal levels again after 25 min. During the peak baseline increases, FP responses to whisker stimulation were similar to saline whereas several haemodynamic response parameters were slightly reduced. After the peak, significant increases in FP responses were observed, accompanied by significantly enhanced haemodynamic responses, even though the haemodynamic baselines remained elevated. Hence, the haemodynamic response to sensory stimulation is transiently reduced in the presence of large increases in baseline but, after the baseline peak, enhanced neural responses are faithfully accompanied by enhanced haemodynamic responses. The findings suggest that any cocaine-induced enhancement of sensory-related neural activity in humans is likely to be detectable by neuroimaging.

Neuroscience Research · Jun 2004

Change in phase synchronization of local field potentials in anesthetized rats after chronic dopamine depletion (opens in a new tab)

Lee KM, Ahn TB, Jeon BS, Kim DG

System IILFP
Abstract

In order to investigate temporal characteristics of oscillatory neural activity and the effect of chronic dopamine depletion on it, local field potentials were measured in anesthetized rats without or with a 6-OHDA lesion at either the ventral tegmental area or the substantia nigra compacta, using a pair of electrodes that were separated by 120 microm. Coupling of neural activity in this mesoscopic scale was measured by a synchronization index that quantified the distribution of differences in instantaneous phase between the two potentials recorded. Phase synchrony was significantly stronger at deep basal ganglia sites, more so than at cortical sites, over a gamma range (30-120 Hz) in normal rats. After chronic dopamine depletion, this synchrony was no longer observable, especially after a substantia nigra lesion, while there was an increase in phase synchrony in the cortex at a lower frequency band (10 Hz). These findings are consistent with previously reported findings that the effect of dopaminergic innervation on oscillatory neural activity varies from synchronizing to desynchronizing, depending on the structure innervated and the frequency of the oscillation.

Journal of Neurophysiology · Jul 2003

Analysis of perisaccadic field potentials in the occipitotemporal pathway during active vision (opens in a new tab)

Purpura KP, Kalik SF, Schiff ND

Abstract

Eye movement potentials (EMPs) associated with saccades appear in both subcortical and cortical structures of the primate visual system. In this study, EMPs are recorded across sites in the occipitotemporal (OT) pathway of monkeys performing a pattern-recognition task. We characterize pair recordings of saccade-triggered local field potentials (LFPs) in early extrastriate and inferotemporal regions of the ventral visual pathway using time-frequency spectrograms. Parameters of the spectrograms, including the centroids of identified regions of interest in the time-frequency plane, are extracted and analyzed. Comparisons among the distributions of the extracted parameters reveal that the occipital lobe EMPs are largely postsaccadic events centered at 100 ms after saccade onset that are typically not influenced in timing by the direction of the saccade or the appearance of a stimulus transient appearing either before or after the saccade. The occipital lobe EMPs also demonstrate a significant shift in frequency content during their transient time course that is influenced, in a few cases, by saccade direction. Temporal lobe EMPs, on the other hand, may be centered in either the presaccadic or postsaccadic intervals; the time of their appearance is significantly influenced by the direction of the saccade. Temporal lobe EMPs demonstrate less frequency modulation than those recorded in the occipital lobe. The prevalence of EMPs in the OT pathway suggests that many cortical regions important for pattern recognition can be modulated by saccades. The timing and frequency characteristics of these signals suggest that the nature of this perisaccadic modulation varies across the cortex.

The Journal of the Acoustical Society of America · Jul 2003

Representation of the voice onset time (VOT) speech parameter in population responses within primary auditory cortex of the awake monkey (opens in a new tab)

Steinschneider M, Fishman YI, Arezzo JC

Abstract

Voice onset time (VOT) signifies the interval between consonant onset and the start of rhythmic vocal-cord vibrations. Differential perception of consonants such as /d/ and /t/ is categorical in American English, with the boundary generally lying at a VOT of 20-40 ms. This study tests whether previously identified response patterns that differentially reflect VOT are maintained in large-scale population activity within primary auditory cortex (A1) of the awake monkey. Multiunit activity and current source density patterns evoked by the syllables /da/ and /ta/ with variable VOTs are examined. Neural representation is determined by the tonotopic organization. Differential response patterns are restricted to lower best-frequency regions. Response peaks time-locked to both consonant and voicing onsets are observed for syllables with a 40- and 60-ms VOT, whereas syllables with a 0- and 20-ms VOT evoke a single response time-locked only to consonant onset. Duration of aspiration noise is represented in higher best-frequency regions. Representation of VOT and aspiration noise in discrete tonotopic areas of A1 suggest that integration of these phonetic cues occurs in secondary areas of auditory cortex. Findings are consistent with the evolving concept that complex stimuli are encoded by synchronized activity in large-scale neuronal ensembles.

Hearing Research · Sep 2002

Onset and offset responses from inferior colliculus and auditory cortex to paired noisebursts: inner hair cell loss (opens in a new tab)

Guo Y, Burkard R

Abstract

Thirteen adult chinchillas were anesthetized with ketamine/acepromazine and tungsten electrodes were placed in the right inferior colliculus (IC) and auditory cortex (AC). A reference electrode was implanted in the anterior cranium. Following a recovery period, AC and IC responses to left ear stimulation were obtained from unanesthetized animals resting in a passive restraint inside a sound-attenuating booth. After the first recording, the animals were injected with carboplatin (75 mg/kg). Four to five weeks later, a second recording was made. Stimuli were 50 ms duration (0 ms rise and fall time), 80 dB SPL noiseburst pairs. In one group of seven animals, the gap time varied from 1 to 64 ms. In a second group of six animals, the gap time ranged from 0.25 to 64 ms in order to determine gap threshold. The responses were amplified (10000x) and filtered from 10 to 3000 Hz. Each response was the average of 100 stimulus presentations. The dependent variables were the latency of the initial positive peak and the amplitude of the response from initial positive peak to the following negativity. Following the second recording, all animals were sacrificed, the cochleas harvested, and cochleograms were obtained by counting outer hair cells (OHCs) and inner hair cells (IHCs). For the onset response to the second noiseburst of each pair, response amplitudes decreased and latencies increased with decreasing gap time. For a 64 ms gap time, the IC response approached the latencies and amplitudes seen for the onset response to the single noiseburst or first noiseburst in the pair (herein called "baseline" values), while the AC response latency approached baseline values, but AC amplitude did not. Interestingly, the offset responses to the first noiseburst were not present at gaps of less than 8 ms, while the onset responses to the second noiseburst were typically present at gaps of 1-2 ms. Cochleograms revealed a normal (or near-normal) complement of OHCs, and IHC loss averaging roughly 30-40% in apical regions and increasing to 60-70% in more basal regions (compared to normative data). Following carboplatin, the latencies of IC onset responses were delayed by several tenths of a millisecond, with the greatest pre- versus post-carboplatin latency shift occurring at short noiseburst gaps. AC response latencies were largely unaffected by carboplatin. IC onset response amplitudes were reduced following carboplatin, while AC onset responses were similar to pre-carboplatin values. IC offset response latencies to the first noiseburst were increased post-carboplatin, while AC offset response latencies varied little from pre-carboplatin values. IC and AC offset response amplitudes to the first noiseburst were decreased post-carboplatin.

Hearing Research · Sep 2002

Neural adaptation to pulsatile acoustical stimulation in the cochlear nucleus of the rat (opens in a new tab)

Loquet G, Rouiller EM

Abstract

This study, carried out in adult Long-Evans rats, was designed to investigate the adaptive properties of the cochlear nucleus to pulsatile acoustical stimuli. To achieve this purpose, near-field evoked potentials were picked up from the ventral cochlear nucleus in awake animals. Individual auditory thresholds were measured and responses to 250 ms trains of repetitive clicks with pulse rates ranging from 100 to 2000 pulses per second were collected. The amplitude of the first negative (N(1)) component of the evoked potentials to consecutive individual pulses in the train was measured by using a subtraction method. As expected, a rapid amplitude decrement of the responses in the train was obtained and a three phase adaptation was described. The decrease of individual N(1) component amplitude was fitted for each rate of stimulation with exponential decrease equations and time constants were calculated. Such an analysis allowed us to characterize three distinct adaptive processes which were discussed. The results were comparable to those obtained in previous studies in the auditory nerve and suggest that the adaptation recorded in the ventral cochlear nucleus by using near-field evoked potentials reflects the adaptive properties of auditory nerve fibers.

Nature Neuroscience · Aug 2002

Temporal structure in neuronal activity during working memory in Macaque parietal cortex (opens in a new tab)

Pesaran B, Pezaris JS, Sahani M, … Andersen RA

Abstract

Many cortical structures have elevated firing rates during working memory, but it is not known how the activity is maintained. To investigate whether reverberating activity is important, we studied the temporal structure of local field potential (LFP) activity and spiking from area LIP in two awake macaques during a memory-saccade task. Using spectral analysis, we found spatially tuned elevated power in the gamma band (25-90 Hz) in LFP and spiking activity during the memory period. Spiking and LFP activity were also coherent in the gamma band but not at lower frequencies. Finally, we decoded LFP activity on a single-trial basis and found that LFP activity in parietal cortex discriminated between preferred and anti-preferred direction with approximately the same accuracy as the spike rate and predicted the time of a planned movement with better accuracy than the spike rate. This finding could accelerate the development of a cortical neural prosthesis.

Physiological Research · 2002

Changes in the acoustically evoked activity in the inferior colliculus of the rat after functional ablation of the auditory cortex (opens in a new tab)

FC Nwabueze-Ogbo, J Popelář, J Syka

Abstract

The role of the cortico-tectal pathways in the processing of auditory signals was investigated by recording the click-evoked responses and extracellular multiple unit activity in the inferior colliculus (IC) after functional ablation of the auditory cortex (AC) by local intracortical application of a sodium channel blocker, tetrodotoxin (TTX). Click-evoked IC responses (IC-ER) and multiple unit activity in response to tone bursts were recorded with implanted electrodes in the IC of rats lightly anaesthetized with xylazine. Neural activity was recorded before and after the application of TTX into the ipsilateral auditory cortex (AC) through three implanted cannulas in a total dose of 30 ng. The functional status of the AC was monitored by recording click-evoked middle latency responses from a ball electrode implanted on the AC. During inactivation of the AC, IC-ER amplitudes were either increased (48 % of the cases), decreased (32 % of the cases) or not evidently changed (20 % of the cases). Corresponding effects were observed in the firing rate of IC neurons. Functional ablation of the AC also resulted in a significant prolongation of the latencies of individual waves of the IC-ER. However, the discharge pattern of the multiple unit responses, response thresholds and tuning were not altered during AC inactivation. IC neural activity recovered within several hours, and maximally during 2 days. The results reveal principles of the interaction of cortico-tectal pathways with IC neuronal activity.

Otology & Neurotology · Nov 2001

Mapping the VIIIth cranial nerve by electrical stimulation: Methods for differentiating auditory from vestibular responses (opens in a new tab)

Berryhill WE, Javel E

System IISigGenEEG/ECoG/EMGLFP
Abstract

Hypothesis The goal of this study was to map the VIIIth cranial nerve by electrical stimulation. Specifically, the authors sought to 1) characterize auditory and vestibular evoked responses elicited by electrical stimuli delivered directly to the exposed surface of the VIIIth cranial nerve and 2) compare electrically evoked responses elicited in brainstem nuclei with extracranially recorded far-field potentials. Background Intraoperative monitoring of auditory brainstem responses is useful during cerebellopontine angle surgery. Identification of the vestibular portion of the VIIIth cranial nerve, which traditionally has been performed by physical characteristics and some electrophysiologic properties, is important because the vestibular subdivision in humans is indistinct in approximately 25% of cases. Positive identification of evoked responses emanating from the vestibular nerve would constitute a marked improvement over existing intraoperative techniques that use acoustic stimuli only. Methods Experiments were performed on 12 anesthetized cats. Electrical pulse stimuli were delivered using a bipolar electrode placed directly on the surface of the exposed VIIIth cranial nerve at several sites. Computer-averaged evoked responses were recorded from far-field electrodes placed on the scalp and from near-field electrodes stereotaxically positioned in or near the inferior colliculus and abducens nucleus. Results Latencies and morphologies of waves recorded in brainstem nuclei were compared with those of waves recorded extracranially. Direct electrical stimulation of the cochlear nerve elicited a four-wave, auditory brainstem response-like extracranial response, strong activity in the inferior colliculus, and weak activity in the abducens nucleus. Direct stimulation of the vestibular nerve produced a two-wave extracranial response, weak inferior colliculus activity, and strong abducens activation. Stimulation at the border of the cochlear and vestibular nerves produced intermediate responses that possessed both cochlear and vestibular characteristics. Conclusion Direct electrical stimulation of the cochlear and vestibular subdivisions elicits evoked responses with distinctly different wave morphologies. Obtaining electrically evoked responses intraoperatively is feasible and may be of substantial value in the unambiguous identification of VIIIth cranial nerve subdivisions.