OpenProject Won't Close
Tech Note: TN2602
Product: OpenEx, OpenWorkbench, OpenProject
Version: All
Date Added: 2026-06-01
Issue
Some Windows updates reset DCOM security and can corrupt OpenWorkbench's permissions, so the close handshake with OpenProject is blocked trying to launch the WorkEngine server. Fixing the Launch & Activation permission restores it. This may be a recurring issue with future Windows updates, so if it happens again run these same steps.
Workaround
- Go to Start > dcomcnfg

- Navigate to Component Services → Computers → My Computer → DCOM Config → right-click on "XpMaker” and select Properties

- In Properties, go to Security → Launch and Activation Permissions → Edit
- Ensure your user/Interactive has Local Launch + Local Activation allowed, with no Deny.)