Hardware

Systems

 

 

High Impedance Headstages


TDT’s high impedance headstages are designed for extracellular neurophysiology using silicon electrodes, metal microelectrodes or microwire arrays. Each headstage offers excellent signal-to-noise (~5 μV rms noise floor) and connects directly to a Medusa preamplifier. Acute headstages include a holding rod allowing them to be attached to a micromanipulator. Chronic headstages are designed to attach directly to implanted electrodes in awake, behaving preparations.

Number of Channels Part # Preparations Gain Probe Connector

64

NN64AC acute 1x 40-pin Samtec FOLC high density socket strip x 2 (1.27mm pins)
32 NN32AC acute 1x 40-pin Samtec FOLC high density socket strip
(1.27mm pins)
16 RA16AC acute 1x 18-pin female Dip socket header (0.5 mm pins)
16 RA16AC4 acute 4x 18-pin female Dip socket header (0.5 mm pins)
16 RA16CH chronic 1x 18-pin female Omnetics Nano dual row header
16 LP16CH chronic 1x 18-pin female Omnetics Nano dual row header
16 SH16 acute (switchable) 1x 18-pin female Dip socket header (0.5 mm pins)
4 RA4AC1 acute 1x 6-pin female header
(0.76 mm pins)
4 RA4AC4 acute 4x 6-pin female header
(0.76 mm pins)
Z-Series compatible versions of most headstages available on request.
See TDT headstage probe adapters.

 

64 and 32-Channel Acute Headstages

This headstage is designed for the 64 and 32-channel acute NeuroNexus probes. Its miniature electronics occupy the same small footprint as our 16-channel acute headstages.

Part numbers:
NN64AC
NN32AC

NN32AC

 

top

16-Channel Acute Headstages

Connect this headstage directly to NeuroNexus acute 16-channel electrodes or use it with metal microelectrodes via a 0.5 mm adaptor. This small form factor is also available with 4x gain.

Part numbers:
RA16AC
RA16AC4 (4x gain)

RA16AC

top

16-Channel Chronic Headstage

The chronic headstage features a low-profile female Omnetics nano connector, and is compatible with TDT microwire arrays as well as NeuroNexus chronic electrodes. The headstage weighs 1.2 g and connects to the preamplifier over a custom cable designed to maximize freedom of movement. The headstage can be used to record from subjects as small as the rat or mouse. The LP16CH low profile headstages provide the same performance with an even smaller footprint, yielding better clearance in tight applications.

Part number:
RA16CH

RA16CH

The LP16CH low profile headstages provide the same performance with an even smaller footprint, yielding better clearance in tight applications. Point to the image below to view both versions side by side.

Part number:
LP16CH


 

top

Four-Channel Acute Headstages

The four channel acute headstages use a low-profile connector for a slim form factor and are available with a unity or 4x gain. This economical 6-pin design provides easy connection to metal microelectrodes for lower channel count systems. The RA4AC1/RA4AC4 is also provided with a 6-pin male connector with flying leads.

Part numbers:
RA4AC1 (low-profile, unity gain)
RA4AC4 (low-profile, 4x gain)

top

16-Channel Switchable Acute Headstage

The switchable headstage features high-voltage, low-leakage solid-state relays to allow remote switching between stimulation and recording on each channel. Relay switching time is 2 ms. The ground line is also switchable, allowing an input channel to instead be used as a reference. The pinout of the SH16 matches the NeuroNexus 16-channel acute electrode, allowing direct connection to the headstage.

Part number:
SH16

top

 

 

 

Also available are our patented
ZIF-Clip® headstages and electrodes
...